Commit graph

13621 commits

Author SHA1 Message Date
Jouni Malinen
4e72b1de1d tests: DPP protocol testing cases for Auth Resp status-not-OK cases
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-27 17:21:22 +02:00
Jouni Malinen
89b6d8a2f0 DPP: Fix no-Status protocol testing in Auth Resp error case
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-27 17:20:41 +02:00
Jouni Malinen
9c976e2c45 tests: Additional DPP AES-SIV local failure coverage
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-27 17:02:31 +02:00
Jouni Malinen
545bf954c4 tests: DPP QR Code and keygen failure
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-27 16:50:36 +02:00
Jouni Malinen
9eadebe3d4 tests: DPP local failure on hashing public key for PKEX bootstrap info
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-27 16:44:48 +02:00
Jouni Malinen
e9bca5b8c3 tests: DPP QR Code and unsupported curve
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-27 16:44:48 +02:00
Sunil Dutt
acecac4c79 Define QCA_NL80211_VENDOR_SUBCMD_LINK_PROPERTIES also as an event
This commit enhances QCA_NL80211_VENDOR_SUBCMD_LINK_PROPERTIES to
also be an event, aimed to notify the link status (EX: connected
stations status on an AP link).

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-27 00:27:18 +02:00
Jouni Malinen
d16be03bd1 tests: Additional DPP bootstrapping URI parsing coverage
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-26 21:35:23 +02:00
Jouni Malinen
01e39ba992 tests: DPP invalid attribute checks
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-26 20:43:30 +02:00
Cedric Izoard
10d32e2c8d nl80211: Use netlink connect socket for disconnect (ext auth)
When external authentication is used, a specific netlink socket is used
to send the connect command. If the same socket is not used for
disconnect command, cfg80211 will discard the command. This constraint
was added into the kernel in commit bad292973363 ("nl80211: Reject
disconnect commands except from conn_owner"). That requires an update
for the hostap.git commit 40a68f3384 ("nl80211: Create a netlink
socket handle for the Connect interface").

Add a new flag into struct i802_bss to indicate if the special
nl_connect socket was used for the connect command. When sending
disconnect command this flag is tested to select the correct socket.

Signed-off-by: Cedric Izoard <cedric.izoard@ceva-dsp.com>
2018-11-26 19:24:31 +02:00
Cedric Izoard
18a0508a41 external-auth: Check key_mgmt when selecting SSID
When selecting SSID to start external authentication procedure also
check the key_mgmt field as several network configuration may be defined
for the same SSID/BSSID pair. The external authentication mechanism is
only available for SAE.

Signed-off-by: Cedric Izoard <cedric.izoard@ceva-dsp.com>
2018-11-26 19:09:25 +02:00
Avraham Stern
a302384148 tests: Call remove_group() after other cleanup is done
The call to remove_group() may fail, in which case all following
cleanup is skipped. This may result in failing many tests since
cleanup did not complete successfully.

Fix this by calling remove_group() after other cleanup is done so
even it fails it will not affect the following tests.

Signed-off-by: Avraham Stern <avraham.stern@intel.com>
2018-11-26 01:00:00 +02:00
Emmanuel Grumbach
941807f6b6 drivers: Document struct wpa_signal_info
Add documentation to the wpa_signal_info structure.
Add a define for an invalid noise value.

Signed-off-by: Emmanuel Grumbach <emmanuel.grumbach@intel.com>
2018-11-26 00:57:50 +02:00
Jouni Malinen
381523ecae tests: hostapd configuration reload on SIGHUP with bss remove/add
Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-26 00:53:53 +02:00
Jouni Malinen
6e7b4c45fa Fix hostapd config file reloading with BSS addition/removal
BSS additional/removal cases were not considered at all in the previous
implementation of hostapd configuration file reloading on SIGHUP. Such
changes resulted in num_bss values getting out of sync in runtime data
and configuration data and likely dereferencing of freed memory (e.g.,
when removing a BSS).

Fix this by forcing a full disable/enable sequence for the interface if
any BSS entry is added/removed or if an interface name changes between
the old and the new configuration.

Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-26 00:51:38 +02:00
Jouni Malinen
cabbaac119 Fix a typo in a comment
Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-26 00:37:24 +02:00
Jouni Malinen
fd1534a258 tests: DPP Connector testing with ECDSA signature in Python
Implement ECDSA signing functionality in the Python test script for
generating a valid signedConnector. This allows coverage of DPP config
object testing to be increased more easily.

Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-25 22:01:35 +02:00
Jouni Malinen
30dda44dcc tests: More DPP Config Object protocol testing coverage
Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-25 20:24:50 +02:00
Jouni Malinen
06e62e11c7 DPP: Fix a debug print to use quotation marks consistently
The "DPP: Unexpected JWK kty" debug print missed one of the quotation
marks.

Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-25 17:31:49 +02:00
Jouni Malinen
a46b60c440 tests: Additional coverage for DPP GAS error cases
These test cases found number of error handling issues in the DPP/GAS
implementation.

Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-25 13:53:05 +02:00
Jouni Malinen
11f07f027a DPP: Fix error path handling for GAS Comeback Response building
A local memory allocation failuring during GAS Comeback Response frame
generation could result in freeing the response context without removing
it from the list. This would result in dereferencing freed memory when
processing the next comeback request.

Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-25 13:51:26 +02:00
Jouni Malinen
c7896ef9c6 DPP: Fix memory leaks in GAS server error path handling
If local memory allocation for the GAS response failed, couple of error
paths ended up leaking some memory maintaining the state for the
exchange. Fix that by freeing the context properly.

Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-25 13:49:44 +02:00
Jouni Malinen
931f7ff656 DPP: Fix GAS client error case handling
The GAS client processing of the response callback for DPP did not
properly check for GAS query success. This could result in trying to
check the Advertisement Protocol information in failure cases where that
information is not available and that would have resulted in
dereferencing a NULL pointer. Fix this by checking the GAS query result
before processing with processing of the response.

Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-25 13:33:39 +02:00
Jouni Malinen
e18b479299 tests: More coverage for ATTACH command parameter setting
Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-25 12:02:07 +02:00
Jouni Malinen
a21eadcf58 tests: D-Bus introspection with busctl
Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-24 18:30:41 +02:00
Lubomir Rintel
d7591aab85 dbus: Expose availability of SHA384 on D-Bus
This lets us know whether we can attempt to use FT-EAP-SHA384.

Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>
2018-11-24 18:18:25 +02:00
Lubomir Rintel
eb7e747931 dbus: Expose availability of FT on D-Bus
This lets us know whether we can attempt to use FT-PSK, FT-EAP,
FT-EAP-SHA384, FT-FILS-SHA256 or FT-FILS-SHA384.

Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>
2018-11-24 18:18:25 +02:00
Lubomir Rintel
8b67f6496e tests: D-Bus Get/Set Pmf
Based on Jouni Malinen's [76055b4c6 "tests: D-Bus Get/Set Pmf"], modified
to use the correct "s" signature for the "Pmf" property.

Removed the negative test cases, because the synthesized property doens't
seem to do error checking upon being set.

Signed-off-by: Jouni Malinen <j@w1.fi>
Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>
2018-11-24 18:04:20 +02:00
Lubomir Rintel
59d59eb0e0 Revert "D-Bus: Implement Pmf property"
This reverts commit adf8f45f8a.

It is basically all wrong. The Pmf property did exist, with a signature of
"s" as documented in doc/dbus.doxygen. It was synthesized from
global_fields[].

The patch added a duplicate one, with a signature of "u", in violation
of D-Bus specification and to bemusement of tools that are careful
enough:

  $ busctl introspect fi.w1.wpa_supplicant1 /fi/w1/wpa_supplicant1/Interfaces/666
  Duplicate property

Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>
2018-11-24 18:03:55 +02:00
Lubomir Rintel
b8d8928f6c Revert "tests: D-Bus Get/Set Pmf"
This is wrong. The Pmf property has a "s" signature.

This reverts commit 76055b4c61.

Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>
2018-11-24 18:03:55 +02:00
Jouni Malinen
4929d556cc mesh: Add Category and Action field to maximum buffer length
Make the buf_len calculation match more closely with the following
wpa_buf*() operations. The extra room from the existing elements was
apparently sufficiently large to cover this, but better add the two
octet header explicitly.

Signed-off-by: Jouni Malinen <j@w1.fi>
2018-11-24 13:36:54 +02:00
Bob Copeland
25778502d5 mesh: Fix off-by-one in buf length calculation
The maximum size of a Mesh Peering Management element in the case
of an AMPE close frame is actually 24 bytes, not 23 bytes, plus the
two bytes of the IE header (IEEE Std 802.11-2016, 9.4.2.102). Found by
inspection.

The other buffer components seem to use large enough extra room in their
allocations to avoid hitting issues with the full buffer size even
without this fix.

Signed-off-by: Bob Copeland <bobcopeland@fb.com>
2018-11-24 13:30:28 +02:00
Davide Caratti
2b7f46f1c7 examples: Fix shellcheck warnings in wps-ap-cli
use 'printf' instead of 'echo -n', to suppress the following warning:

In POSIX sh, echo flags are undefined. [SC2039]

Signed-off-by: Davide Caratti <davide.caratti@gmail.com>
2018-11-22 15:53:30 +02:00
Andrei Otcheretianski
79bbafd78c tests: Store the correct PID in hostapd-test.pid file
The hwsim's start.sh script spawns hostapd process using "sudo".
Since sudo forks a child process, $! holds the pid of sudo itself.
Fix that by storing the PID of the child process instead.
Since in VM "sudo" is replaced with a dummy script, pass an additional
argument to run-all.sh and start.sh scripts to indicate that they are
running inside a VM.

This is needed to fix ap_config_reload and ap_config_reload_file test
cases on some platforms where sudo is apparently not relaying the
signals properly.

Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
2018-11-22 15:53:30 +02:00
Ayala Beker
fcc65290d4 tests: Fix ap_acl_deny test
In ap_acl_deny test, the AP doesn't send probe responses during scan due
to ACL reject. As the result, dev[0] might miss the AP's Beacon frame
because the dwell time is too short. Make the test more robust and
trigger passive scan, and by that increase the probability of hearing
the AP.

Signed-off-by: Ayala Beker <ayala.beker@intel.com>
2018-11-22 15:53:30 +02:00
Johannes Berg
babdd8d0d9 nl80211: Use correct u8 size for NL80211_ATTR_SMPS_MODE
Back in December 2017, Jouni fixed the output side since that was
causing a kernel message to be printed, but the input side should
also be fixed, otherwise it will not work correctly on big-endian
platforms.

Signed-off-by: Johannes Berg <johannes.berg@intel.com>
2018-11-22 15:53:30 +02:00
Damodaran, Rohit (Contractor)
cd676ae34c Fix dpp_configurator_get_key command name in hostapd_cli
The option to get DPP configurator key in hostapd_cli was named
incorrectly. It was wrongly pointing to dpp_configurator_remove. Fix
this by using the correct name.

Signed-off-by: Rohit Damodaran <Rohit_Damodaran@comcast.com>
2018-11-22 15:53:26 +02:00
Jouni Malinen
adbce7443d HS 2.0: Update HS2.0 AP version RADIUS attribute Version field
Use HS20_VERSION macro to determine if R3 should be indicated instead of
R2.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-09 23:38:31 +02:00
Jouni Malinen
524b963c6c tests: Mark OSU BSS explicitly in sigma_dut_ap_hs20
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-09 18:10:28 +02:00
Jouni Malinen
db368b2e13 tests: ap_hs20_osen to test group cipher selection in SME case
Go through the group cipher selection in both the wpa_supplicant and
driver SME cases.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-09 18:09:34 +02:00
Jouni Malinen
dc673aec46 HS 2.0: Generate AssocReq OSEN IE based on AP advertisement
Parse the OSEN IE from the AP to determine values used in the AssocReq
instead of using hardcoded cipher suites. This is needed to be able to
set the group cipher based on AP advertisement now that two possible
options exists for this (GTK_NOT_USED in separate OSEN BSS; CCMP or
GTK_NOT_USED in shared BSS case). Furthermore, this is a step towards
allowing other ciphers than CCMP to be used with OSEN.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-09 18:07:16 +02:00
Sachin Ahuja
d554402140 Define new QCA vendor command for coex priority config
Add QCA_NL80211_VENDOR_SUBCMD_COEX_CONFIG vendor command
to set the priorities among different types of traffic of
WLAN/BT/Zigbee during coex scenarios.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-09 00:20:09 +02:00
vamsi krishna
a626fb1070 Add QCA vendor event to indicate throughput changes
Add interface for drivers to report changes in TX/RX throughput
dynamically to user space. This information can be used by userspace
tools to tune kernel's TCP parameters in order to achieve peak
throughput. The driver may optionally provide guidance on which TCP
parameters to be configured for optimal performance along with the
values to be configured.

The TCP parameters that need to be tuned for peak performance are not
interface specific. Based on the guidance from the driver and
considering the other interfaces that may be affected with the new
configurations, a userspace tool has to choose the values to be
configured for these parameters to achieve optimal performance across
interfaces.

The throughput levels informed by the driver with this event are only
for providing guidance on TCP parameter tuning from userspace. The
driver may change the thresholds used to decide low or medium or high
throughput levels based on several parameters based on the PHY layer
capacity in the current connection, the number of packets being
dispatched per second, or the number of packets pending in queues, etc.
The throughput levels may not be consistent with the actual throughput
of the link.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-08 21:56:58 +02:00
Jouni Malinen
b583907b53 tests: Use more correct OSU_METHOD value in sigma_dut_ap_hs20
The OSU Providers List includes two providers, so there should be two
OSU_METHOD values listed just like there was two OSU_SERVER_URI URLs.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-06 02:04:09 +02:00
Jouni Malinen
4902eb04b1 tests: Use bridge in sigma_dut_ap_eap_osen
This is needed to allow sigma_dut to enable ap_isolate=1. In addition,
verify that the two associated STAs with RSN(EAP) and OSEN cannot
exchange frames between them.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-06 00:46:23 +02:00
Kiran Kumar Lokere
5d332a13f7 Add test config QCA vendor attribute for action frame Tx in TB PPDU
Add a new wifi test config QCA vendor attribute to configure action
frame transmission in HE trigger based PPDU.
This is used for testbed configuration.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-02 12:10:18 +02:00
Kiran Kumar Lokere
a94aab6ddd Define test config QCA vendor attribute for HE SU PPDU Tx config
Add a new wifi test config QCA vendor attribute to configure HE
single user PPDU transmission.
This is used for testbed configuration.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-02 12:09:38 +02:00
Kiran Kumar Lokere
292bce08b3 Define test config QCA vendor attribute for HE OM control config
Add a new wifi test config QCA vendor attributes to configure HE
operating mode control field bandwidth, number of spatial streams, and
UL MU disable configuration. Define a new attribute to clear the
previously set HE OM control field configuration. This is used for
testbed configuration.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-02 12:09:22 +02:00
Jouni Malinen
e7869a664a tests: sigma_dut AP configuration for Hotspot 2.0
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-11-01 17:10:40 +02:00
Jouni Malinen
ab3ab50757 HS 2.0: Fix Terms and Conditions URL handling
Do not try to determine the length of the T&C Server URL before checking
that the URL is available. This got broken in a change to move the
handling to the AS. hostapd could potentially have hit a NULL pointer
dereference if the authentication server sent an unconsistent set of T&C
information.

Fixes: d4e39c51f8 ("HS 2.0: Move Terms and Conditions Server URL generation from AP to AS")
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-10-30 19:15:11 +02:00