Commit 0f44ec8eba ('Add a reattach command
for fast reassociate-back-to-same-BSS') added Reattach(), but forgot to
document it.
Signed-off-by: Jouni Malinen <j@w1.fi>
Commit 7a4a93b959 ('dbus: Add SignalPoll()
method to report current signal properties') added this method, but
forgot to document it.
Signed-off-by: Jouni Malinen <j@w1.fi>
This property was added to the fi.w1.wpa_supplicant1 interface in commit
1634ac0654 ('dbus: Add global capabilities
property'), but documentation was not updated.
Signed-off-by: Jouni Malinen <j@w1.fi>
The "Bridge_ifname" parameter had been renamed to "BridgeIfname" and
"ConfigFile" is also available as a parameter.
Signed-off-by: Jouni Malinen <j@w1.fi>
It looks like the space indentation before the HTML command ended up
being converted to HTML tags getting shown as code text rather than
being used to control formatting. Fix this by removing indentation from
the first line of each HTML segment.
Signed-off-by: Jouni Malinen <j@w1.fi>
This was already verified to be non-NULL above and there is no point in
having an extra check after the pointer has already been dereferenced.
Signed-off-by: Jouni Malinen <j@w1.fi>
wpas_dbus_decompose_object_path() may leave the network part NULL on
unexpected path. This resulted in NULL pointer dereference when
processing an invalid removeNetwork or selectNetwork call. Fix this by
explicitly verifying that the network part was included in the object
path.
Signed-off-by: Jouni Malinen <j@w1.fi>
The "Invalid blob name" string was not shown since the zero-length name
was used regardless of first verifying that it should not be allowed.
Signed-off-by: Jouni Malinen <j@w1.fi>
External WPS Registrar operation requires the BSSID to be specified, so
the old D-Bus interface better apply that requirement as well.
Signed-off-by: Jouni Malinen <j@w1.fi>
It is possible for the persistent group object to be added and removed
by non-D-Bus triggers (e.g., ctrl_iface commands). The add part was
already handled, but removal was not. That resulted in memory leaks when
a P2P persistent group was removed without using an explicit D-Bus
command for this even if the object was added without D-Bus involvement.
Signed-off-by: Jouni Malinen <j@w1.fi>
wpas_dbus_simple_property_getter() cannot be used with NULL
DBUS_TYPE_STRING, so replace that with an empty string to handle the
case of no config_methods parameter in the configuration.
Signed-off-by: Jouni Malinen <j@w1.fi>
It is possible for the peer to be a non-P2P device and as such, for
p2p_dev_addr to be NULL. This resulted in NULL pointer dereference if
D-Bus interface was enabled for the interface when a legacy STA joined a
group.
Signed-off-by: Jouni Malinen <j@w1.fi>
It was possible for old scan state to remain from a previous test case
when an operation like WNM neighbor scan or another-BSS-in-ESS was
started, but stopped at the end of a test case. This could result in
failures, e.g., when running wnm_bss_tm_req followed by scan_setband.
Signed-off-by: Jouni Malinen <j@w1.fi>
If hostapd will use stdout for debugging, set stdout to be line
buffered in case its output is redirected to a file. This allows
incremental output to be viewed immediately instead of at the file
buffering interval.
Signed-hostap: Paul Stewart <pstew@chromium.org>
It isn't mandatory. If we need one and it's not present, the ENGINE will
try asking for it. Make sure it doesn't actually let an OpenSSL UI loose,
since we don't currently capture those.
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
It needs to be available to ENGINE_by_id(), which in my case means it
needs to be /usr/lib64/openssl/engines/libpkcs11.so. But that's a system
packaging issue. If it isn't there, it will fail gracefully enough with:
ENGINE: engine pkcs11 not available [error:25066067:DSO support routines:DLFCN_LOAD:could not load the shared library]
TLS: Failed to set TLS connection parameters
EAP-TLS: Failed to initialize SSL.
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
This means that if the PKCS#11 engine is installed in the right place
in the system, it'll automatically be invoked by ENGINE_by_id("pkcs11")
later, and things work without explictly configuring pkcs11_engine_path.
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
If these start with "pkcs11:" then they are PKCS#11 URIs. These Just Work
in the normal private_key/ca_cert/client_cert configuration fields when
built with GnuTLS; make it work that way with OpenSSL too.
(Yes, you still need to explicitly set engine=1 and point to the engine,
but I'll work on that next...)
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
There's no reason I shouldn't be able to use PKCS#11 for just the CA cert,
or even the client cert, while the private key is still from a file.
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
New versions of engine_pkcs11 will automatically use the system's
p11-kit-proxy.so to make the globally-configured PKCS#11 tokens available
by default. So invoking the engine without an explicit module path is
not an error.
Older engines will fail but gracefully enough, so although it's still an
error in that case there's no need for us to catch it for ourselves.
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
This leaves the build tree with valid wpa_supplicant object files in the
end and makes it a bit easier to do additional custom builds when
needed.
Signed-off-by: Jouni Malinen <j@w1.fi>
Previously, these test cases were marked as failures, but it is nicer to
mark as skipped if the kernel does not include support for mesh.
Signed-off-by: Jouni Malinen <j@w1.fi>
Some of the newer dfs_radar* test cases did not allow hostapd
startup to fail. Since these require relatively recent kernel
support, mark the test cases with skip rather than fail based
on that step failing.
Signed-off-by: Jouni Malinen <j@w1.fi>
ap_ht_smps needs relatively recern kernel support, so allow it to be
skipped rather than claimed as failure, in case hostapd startup fails.
Signed-off-by: Jouni Malinen <j@w1.fi>
It was possible for the separate builds to not include
wpa_cli/hostapd_cli in the default location. Make sure hostapd_cli gets
built for --codecov cases and update both WPACLI and HAPDCLI paths to
match the alternative location.
Signed-off-by: Jouni Malinen <j@w1.fi>
Large number of test cases will fail if hostapd fails to start as the
RADIUS server. To make this more obvious, verify that the RADIUS server
instance is running and do not even start test execution if the setup if
not work properly.
Signed-off-by: Jouni Malinen <j@w1.fi>
It was possible for the scr.addstr() operations to fail and terminate
parallel-vm.py if the number of failed test cases increased beyond what
fits on the screen.
Signed-off-by: Jouni Malinen <j@w1.fi>
This converts most of the remaining perror() and printf() calls from
hostapd and wpa_supplicant to use wpa_printf().
Signed-off-by: Jouni Malinen <j@w1.fi>
It's possible to jump through hoops to support it in older versions too,
but that seems a little unnecessary at this point.
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
'_t' suffix for gnutls_session and gnutls_transport_ptr was added in
GnuTLS 1.1.11 over ten years ago and the more recent versions of GnuTLS
have started forcing compiler warnings from the old names. Move to the
new names and don't bother about backwards compatibility with older
versions taken into account how long ago this change happened in GnuTLS.
Signed-off-by: Jouni Malinen <j@w1.fi>
struct wpa_driver_associate_params moved to using struct
hostapd_freq_params instead of just frequency. Need to update wpa_priv
to do same.
Signed-off-by: Jouni Malinen <j@w1.fi>
Some of the struct hostapd_data variables get initialized with allocated
memory in the P2P GO case even before hapd->started has been set to 1.
As such, hostapd_free_hapd_data() needs to free these even if
!hapd->stated.
Signed-off-by: Jouni Malinen <j@w1.fi>
Even if the UUID would have a mismatch, e.g., due to no UUID known for
the target in a new WPS PBC instance, do not indicate PBC session
overlap if the BSSID is same in the two entries. This should not really
happen in normal use cases, but can happen at least in some test
scenarios where the same BSSID is used in consecutive test cases and the
old BSS entry remains in cfg80211 cache.
Signed-off-by: Jouni Malinen <j@w1.fi>
Wait for a CTRL-EVENT-REGDOM-CHANGE even before returning from
set_country() to avoid issues with test operations being executed before
all components have had chance to update their regulatory domain
information. Some of these test cases could fail under heavy load.
Signed-off-by: Jouni Malinen <j@w1.fi>
Merge partial lines together before processing them in parallel-vm.py.
This avoids issues in cases where the stdout read gets split into pieces
that do not include the full READY/PASS/FAIL/SKIP information. In
addition, strip unnecessary whitespace (mainly, '\r') from the log
lines.
Signed-off-by: Jouni Malinen <j@w1.fi>