Once mac80211 starts reporting the used Association Request frame IEs in
the association event, wpa_supplicant will update RSN supplicant IE
information based on that and that will make the AP reject EAPOL-Key msg
2/4 in this particular test scenario due to the hack of including two
RSN IEs in the Association Request frame. Accept this sequence as a
valid test execution in addition to the previously expected connection
to avoid reporting incorrect failures.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This allows unexpected cases to terminate parallel-vm.py without being
hidden by the exception handler.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
The result of reading non blocked empty stream is different between
python2 and 3. The python2 sends "[Errno 11] Resource temporarily
unavailable" exception. The python3 could read "None" without
exception, so handle this "None" case as well.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
In recent Debian versions, ebtables is an alias managed by
the alternatives(8) mechanism. This means /usr/sbin/ebtables
is a symlink to /etc/alternatives/ebtables, which in turn
links to the real binary.
As we mount a tmpfs over /etc, we cannot access this.
Fix this by bind-mounting the real /etc to /tmp/etc and
adding a symlink from /etc/alternatives to this.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Evidently this file must exist when running the sigma_dut
dependent tests, add it to .gitignore so it's not seen as
making the tree "unclean" when it is added manually.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
For tests, build the HS 2.0 OSU client (without browser to avoid
having webkit/curl dependencies).
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Add a test that drops the authentication frame, so that
hostapd thinks the station is unknown, and then sends one
by itself, so the station thinks it's associated. This
tests mostly the kernel's capability to recover from this
scenario.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
If telnetd is installed and --telnet <port> is passed on the
vm-run.sh command line, start a telnet server (directly connected
to bash, no login) inside the VM(s) to be able to look into them
when something is wrong. Use a user network in qemu with a single
host forward from the specified port for this, listening only on
'localhost'.
Please note that this provides unauthenticated access to the guest
system from anything that can open a TCP connection on the host system.
The guess system does have access to reading all files on the host that
the user account running kvm has access to (and even write access if the
default ROTAG ,readonly parameter is cleared). In other words, this
option should not be used on any multiuser systems where kvm is run
under user accounts that are not dedicated for testing purposes (i.e.,
do not have access to any files that should not be readable to
everyone).
This needs CONFIG_VIRTIO_NET=y in the guest kernel.
For parallel-vm.py, the --telnet argument specifies the base port
and each VM index (0, 1, ...) is added to it.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Recently, qemu/seabios grew an annoying console/terminal reset,
which also causes my terminal to be left in a state where long
lines don't work well and less gets confused because of this.
Suppress this by suppressing all output from qemu before a new
magic string printed from inside.sh.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Instead of relying on existing configuration (which may conflict
with other tests) and skipping otherwise, create a new radio with
two channels in this test and use it.
Signed-off-by: Jouni Malinen <j@w1.fi>
Instead of relying on existing configuration (which may conflict
with other tests) and skipping otherwise, create a new radio with
two channels in this test and use it.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
This is needed to fix issues with dict iteration resulting in different
order of attributes when trying to calculate Message-Authenticator
externally to pyrad.
Signed-off-by: Jouni Malinen <j@w1.fi>
All other test cases seem to work, but radius_das_disconnect_time_window
is still failing due to incorrect authenticator or Message-Authenticator
in Disconnect-Request.
Signed-off-by: Jouni Malinen <j@w1.fi>
Sending UTF-8 encoded data to logger file is currently not working
properly, so create a separate binary file with a copy of
sigma_dut-ap.conf instead to work with both python2 and python3.
Signed-off-by: Jouni Malinen <j@w1.fi>
Use struct.unpack() to get a list of int and then generate a list of
hexstr octets from it for ':'.join() to get consistent behavior for both
python2 and python3.
Signed-off-by: Jouni Malinen <j@w1.fi>
WPSAPHTTPServer class needs to explicitly decode the read value from
a bytes object to a str object.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Use ET.tostring() to avoid implicit bytes/str conversion issues within
ET implementation. Add XML declaration separately to match previous
behavior.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
This is needed for python3 since the two argument version of
str.translate() is not available for unicode. Furthermore, these cases
of delete colons from the string are simple enough for replace.
Signed-off-by: Jouni Malinen <j@w1.fi>
Only python3 warns to this bug.
TypeError: '>' not supported between instances of 'type' and 'int'
Exception: '>' not supported between instances of 'type' and 'int'
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>