The Linux kernel commit 113f3aaa81bd ("cfg80211: Prevent regulatory
restore during STA disconnect in concurrent interfaces") broke the
regulatory clearing attempt in many test cases since
cfg80211_is_all_idle() is now returning false due to the AP interface
being up and that results in the Country IE -based regulatory
information not getting cleared back to defaults.
Work around this by stopping the AP interface first so that when the
station interface receives the disconnection, there are no other active
interfaces in the system. In addition, wait for REGDOM event for the
Country IE hint after association to avoid disconnection before the
regulatory events have been fully processed.
Signed-off-by: Jouni Malinen <j@w1.fi>
In ap_acl_deny test, the AP doesn't send probe responses during scan due
to ACL reject. As the result, dev[0] might miss the AP's Beacon frame
because the dwell time is too short. Make the test more robust and
trigger passive scan, and by that increase the probability of hearing
the AP.
Signed-off-by: Ayala Beker <ayala.beker@intel.com>
HT cannot be used with WEP-only network, so don't try to do that here.
This get rids of some unnecessary Beacon frame updates during
disassociation/association and can make the test case a bit more robust.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
This extends the ap_wds_sta test case to cover post-reassociation case
(both with and without Authentication frame exchange) and add similar
test cases to cover open and WEP cases in addition to this existing
WPA2-PSK test case.
These cover functionality testing for the previous fix in
reassociation-without-new-authentication case. In addition, these find a
new mac80211 issue for the WEP + 4addr combination.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
After successfully passing the 525 tests on a remote setup mark the
tests as remote compatible.
Signed-off-by: Jonathan Afek <jonathanx.afek@intel.com>
The hwsim tests used to execute shell commands in the tests using the
subprocess python module. Use the cmd_execute() general function for
executing shell commands to setup bridge so that this would also work on
remote setups.
Signed-off-by: Jonathan Afek <jonathanx.afek@intel.com>
The hwsim tests used to execute shell commands in the tests using the
subprocess python module. Use the cmd_execute() general function for
executing "iw reg set 00" so that this would also work on remote setups.
Signed-off-by: Jonathan Afek <jonathanx.afek@intel.com>
Pass the full apdev to the add_ap() function instead of just ifname.
This allows us to handle also remote hosts while we can check
apdev['hostname'], apdev['port'].
This step (1) converts the cases where apdev[#]['ifname'] was used as
the argument to hostapd.add_ap().
Signed-off-by: Janusz Dziedzic <janusz.dziedzic@tieto.com>
It was possible for the AP's Beacon frame to be seen by dev[0] when
running a scan. This is not an error case. Make this test case more
robust by verifying with a sniffer whether a Probe Response frame was
sent to unexpected STA.
Signed-off-by: Jouni Malinen <j@w1.fi>
run-tests.py is running as root, so sudo does not need to be used
anymore from within each test case.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
It was possible for regulatory domain changes to "leak" into following
test cases in number of cases where the cfg80211 BSS table remained
after regulatory domain had been restored to world roaming. Try to make
this less likely to occur by explicitly clearing BSS table at the end of
test cases that use different regulatory domain. This makes P2P test
cases that verify channel selection based on world roaming rules more
robust.
Signed-off-by: Jouni Malinen <j@w1.fi>
External tool is not needed anymore to run the data connectivity tests
since hostapd test mode now allows the possible bridge or VLAN interface
to be specified.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
This makes it easier to replace data connectivity testing to use
something else than local hwsim_test binary on the controller device.
Signed-off-by: Jouni Malinen <j@w1.fi>
Only run-tests.py is actually executed, so there is no need to specify
the interpreter in all the helper files and test script files.
Signed-off-by: Jouni Malinen <j@w1.fi>