Since 3bdc651a62, start.sh creates the logs/current symlink even if
LOGDIR was set in the environment, as is the case when using run-all.sh.
However, run-all.sh and start.sh use a separate 'date' invocation so the
resulting string may be different. Usually it is the same because the
two invocations immediately follow each other, *except* if run-all.sh
also does a build. In addition, if the user sets LOGDIR to something
else, the symlink is completely bogus.
Fix this by not relying on the 'date' invocation for creating the
symlink. Instead, use the basename of LOGDIR. To keep things consistent
with current behavior, only create the symlink if LOGDIR points to a
subdirectory of DIR/logs.
The following use cases now work reliably:
* run-all.sh with or without the -B option;
* manually calling start.sh followed by run-tests.py without setting
LOGDIR.
* manually calling start.sh with LOGDIR set to a subdirectory of logs
and calling run-tests.py without --logdir option (which makes it
default to logs/current).
* run-all.sh with LOGDIR set to a subdirectory of logs.
Signed-off-by: Arnout Vandecappelle (Essensium/Mind) <arnout@mind.be>
This is in preparation for an implementation change that results in this
unreachable server case not incrementing radiusAuthClientAccessRequests.
Signed-off-by: Jouni Malinen <j@w1.fi>
These checks were repeated in almost every test case, so use helper
functions to get rid of duplicated (copy-pasted) code.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add even more workarounds for cfg80211 regulatory state clearing since
these DFS test cases seem to be the most likely ones to fail due to
country=98 issues.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add even more workarounds for cfg80211 regulatory state clearing since
these DFS test cases seem to be the most likely ones to fail due to
country=98 issues.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add even more workarounds for cfg80211 regulatory state clearing since
these WNM test cases seem to be the most likely ones to fail due to
country=98 issues.
Signed-off-by: Jouni Malinen <j@w1.fi>
In addition, add even more workarounds for cfg80211 regulatory state
clearing since this test case seems to be the most likely one to fail
due to country=98 issues.
Signed-off-by: Jouni Malinen <j@w1.fi>
This is a regression test case for FT-over-DS that got broken on
mac80211-based drivers when the extra key reinstallation checks were
added.
Signed-off-by: Jouni Malinen <j@w1.fi>
ap_ft_oom seemed to depend on undesired wpa_supplicant behavior of
trying to do FT protocol even without being ready for reassociation.
This is going to be fixed in wpa_supplicant which would make this test
case fail, so split it into separate test cases for each failure item to
be able to avoid incorrect test failures.
Signed-off-by: Jouni Malinen <j@w1.fi>
The previous roam() and roam_over_ds() checks would have ignored failing
association rejection if a consecutive attempt to connect succeeds
within the initial time limit. This can miss incorrect behavior, so
check explicitly for association rejection.
Signed-off-by: Jouni Malinen <j@w1.fi>
The number of direct allocation within wpa_supplicant_mesh_init()
has been reduced due to RSN init function is factored out.
Signed-off-by: Peter Oh <peter.oh@bowerswilkins.com>
Verify that the beacon report contains the last beacon report
indication subelement when requested in the beacon request.
Signed-off-by: Avraham Stern <avraham.stern@intel.com>
Verify that when the frame body subelement causes the
measurement report element to exceed the maximum element size,
the beacon report is fragmented and the frame body fragment ID
subelement is added with the correct fragment number.
Signed-off-by: Avraham Stern <avraham.stern@intel.com>
Verify that not updating GTK (i.e., only update PTK) in the driver does
not break connectivity. This case is different after the check for
"already in-use GTK" and rejection of GTK reinstallation.
Signed-off-by: Jouni Malinen <j@w1.fi>
Use of country=00 (world roaming) seemed to not work anymore with the
current cfg80211 regulatory implementation since the existing channel is
left enabled when moving to country=00. Use a specific country code that
does enforce the selected channel from being used anymore to make this
test case pass again.
The change in cfg80211 behavior is from the kernel commit 113f3aaa81bd
("cfg80211: Prevent regulatory restore during STA disconnect in
concurrent interfaces").
Signed-off-by: Jouni Malinen <j@w1.fi>
With this command, RSSI signal can be controlled. Due to restrictions in
kernel, only values in the range of [-30, -50] can be used. The command
is implemented by changing the TX power.
Signed-off-by: Beni Lev <beni.lev@intel.com>
It was possible for the 5 GHz PKEX channels to be enabled, e.g., when
running "ap_ht40_csa2 dpp_pkex_no_responder" test sequence, and that
resulted in a failure in dpp_pkex_no_responder due to the unexpectedly
long wait needed for the DPP-FAIL event. Increase the wait time to allow
for 5 GHz PKEX channels to be probed.
Signed-off-by: Jouni Malinen <j@w1.fi>
This allows more accurate logging of failures related to the cfg80211
country=98 (intersection) case. This version is trying to give some more
time to allow the country code to clear, but that does not seem to be
sufficient with the current cfg80211 implementation for country=98 (but
might be for other cases).
The additional check for country=98 at the beginning of each test case
is an attempt to force cfg80211 to restore world roaming state with a
new association and disconnection at the station side detected after the
AP side has already stopped. This is needed after the Linux kernel
commit 113f3aaa81bd ("cfg80211: Prevent regulatory restore during STA
disconnect in concurrent interfaces").
Signed-off-by: Jouni Malinen <j@w1.fi>
This is needed to avoid leaving unexpected cfg80211 regulatory country
code in place at the point when a test case terminates.
Signed-off-by: Jouni Malinen <j@w1.fi>
Previously, the special value 0 was used to indicate no UDP checksum.
Replace that with the calculated checksum for more like use case.
Signed-off-by: Jouni Malinen <j@w1.fi>
The ap_open_tdls_vht* test cases could leave some pending regulatory
Beacon hints waiting to be cleared during the following test case. This
would result in a failure if the following test case expected specific
regdom event behavior. For example, this caused "ap_open_tdls_vht160
dbus_country" sequence to result in failure in dbus_country. Fix this by
using more robust sequence in clearing regdom state at the end of the
TDLS test cases that have the AP advertising a country code.
Signed-off-by: Jouni Malinen <j@w1.fi>
Not all driver interfaces provide driver status information with the
local address, so skip the override step if the field is not available.
This is needed, e.g., with macsec_linux.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add a new test to check that the AP won't send frames to the client if
it tries to talk to itself.
Note that this fails until the relevant mac80211 patch is merged.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
These test cases seemed to have copy-paste errors where
wait_enabled=False was forgotten even though there was no additional
steps checking the AP mode startup results. This did not break the
tests, but could have resulted in slowing them down if the STAs did not
find the AP in the first scan.
Signed-off-by: Jouni Malinen <j@w1.fi>
The Linux kernel commit 113f3aaa81bd ("cfg80211: Prevent regulatory
restore during STA disconnect in concurrent interfaces") broke the
regulatory clearing attempt in many test cases since
cfg80211_is_all_idle() is now returning false due to the AP interface
being up and that results in the Country IE -based regulatory
information not getting cleared back to defaults.
Work around this by stopping the AP interface first so that when the
station interface receives the disconnection, there are no other active
interfaces in the system. In addition, wait for REGDOM event for the
Country IE hint after association to avoid disconnection before the
regulatory events have been fully processed.
Signed-off-by: Jouni Malinen <j@w1.fi>
The Linux kernel commit 113f3aaa81bd ("cfg80211: Prevent regulatory
restore during STA disconnect in concurrent interfaces") broke the
regulatory clearing attempt in this test case since
cfg80211_is_all_idle() is now returning false due to the AP interface
being up and that results in the Country IE -based regulatory
information not getting cleared back to defaults.
Work around this by stopping the AP interface first so that when the
station interface receives the disconnection, there are no other active
interfaces in the system. In addition, wait for REGDOM event for the
Country IE hint after association to avoid disconnection before the
regulatory events have been fully processed.
Signed-off-by: Jouni Malinen <j@w1.fi>
cfg80211 regulatory code gets into pretty inconvenient state if it needs
to intersect regulatory domain information from multiple regulations
(country=98). The existing mechanisms in the hwsim test cases are not
able to clear that up for the following test case and this can result in
large number of failures.
It looks like country=98 case is hit frequently in WNM test cases where
a station associates with an AP that advertises a specific country code
and that station is then asked to disconnect before the REGDOM events
have been received. Avoid this by waiting for the REGDOM events for the
init=COUNTRY_IE case before disconnecting.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This adds some minimal testing for Multi-BSS connection attempts. The
part for nontransmitted BSS is limited since hostapd/mac80211 does not
yet have sufficient support for Multi-BSS in AP mode.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Perform detailed tests with OCV enabled, for both the 4-way and group
key handshakes. These tests include establishing a working connection
with OCV enabled, assuring that a STA without OCV enabled can still
connect to a STA with OCV enabled (and vice versa), verifying that
invalid OCI elements get silently ignored, verifying that missing OCI
elements are reported, and so on.
Signed-off-by: Mathy Vanhoef <Mathy.Vanhoef@cs.kuleuven.be>
parallel-vm.py has obsoleted this a long time ago and there is no need
to maintain two scripts for doing more or less the same thing.
Signed-off-by: Jouni Malinen <j@w1.fi>
Now that hostapd starts mandating PMF for Hotspot 2.0 Release 2
association, this test case needs some more tweaks to work. Hardcode
Hotspot 2.0 Release 1 to be used and disable PMF explicitly.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The Beacon loss event was not reported anymore, so remove that as an
unnecessary step in the test case. In addition, check the key_mgmt
values explicitly.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This is needed to meet the Hotspot 2.0 Release 2 requirement for the
third station that is actually using RSN.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Match the implementation change to fix the test cases that verified a
specific Hotspot 2.0 release number indication.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This is a regression test case for a potential NULL pointer
dereferencing fixed in the previous commit.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This verifies that radio measurement capabilities are negotiated
correctly for the reassociation cases with and without FT.
Signed-off-by: Jouni Malinen <j@w1.fi>
There is no point in building this tarball in /tmp that is on the
ramdisk of the VM since it will go away when the VM exits.
Signed-off-by: Jouni Malinen <j@w1.fi>
The call to remove_group() may fail, in which case all following
cleanup is skipped. This may result in failing many tests since
cleanup did not complete successfully.
Fix this by calling remove_group() after other cleanup is done so
even it fails it will not affect the following tests.
Signed-off-by: Avraham Stern <avraham.stern@intel.com>
Implement ECDSA signing functionality in the Python test script for
generating a valid signedConnector. This allows coverage of DPP config
object testing to be increased more easily.
Signed-off-by: Jouni Malinen <j@w1.fi>
Based on Jouni Malinen's [76055b4c6 "tests: D-Bus Get/Set Pmf"], modified
to use the correct "s" signature for the "Pmf" property.
Removed the negative test cases, because the synthesized property doens't
seem to do error checking upon being set.
Signed-off-by: Jouni Malinen <j@w1.fi>
Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>
The hwsim's start.sh script spawns hostapd process using "sudo".
Since sudo forks a child process, $! holds the pid of sudo itself.
Fix that by storing the PID of the child process instead.
Since in VM "sudo" is replaced with a dummy script, pass an additional
argument to run-all.sh and start.sh scripts to indicate that they are
running inside a VM.
This is needed to fix ap_config_reload and ap_config_reload_file test
cases on some platforms where sudo is apparently not relaying the
signals properly.
Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
In ap_acl_deny test, the AP doesn't send probe responses during scan due
to ACL reject. As the result, dev[0] might miss the AP's Beacon frame
because the dwell time is too short. Make the test more robust and
trigger passive scan, and by that increase the probability of hearing
the AP.
Signed-off-by: Ayala Beker <ayala.beker@intel.com>
The OSU Providers List includes two providers, so there should be two
OSU_METHOD values listed just like there was two OSU_SERVER_URI URLs.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This is needed to allow sigma_dut to enable ap_isolate=1. In addition,
verify that the two associated STAs with RSN(EAP) and OSEN cannot
exchange frames between them.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
P2P related configuration should be done on a global control interface.
This way this test can be reused also when a dedicated P2P device
interface is used.
Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>