When a mesh point reconnects by starting from Authentication frame
sequence, the plink count was not decremented from its last connection.
This resulted in leaking peer link count and causing wpa_supplicant to
reject the connection after max_peer_links (default: 99) reconnects.
This was reproduced by pre-configuring 2 mesh points with mesh
credentials. Boot both mesh points and make sure they connect to each
other. Then in a loop reboot one of the mesh points after it
successfully connects while leaving the other mesh point up and running.
After 99 iterations the supplicant on mesh point that is not rebooting
will reject the connection request from the other mesh point.
Fix this by decrementing num_plinks when freeing a STA entry that is
still in PLINK_ESTAB state.
Signed-off-by: Srinivasa Duvvuri <sduvvuri@chromium.org>
The plink_state exists both wpa_supplicant and kernel. Synchronize them
with wpa_mesh_set_plink_state().
Signed-off-by: Kenzoh Nishikawa <Kenzoh.Nishikawa@jp.sony.com>
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Add timer to do SAE re-authentication with number of tries defined
by MESH_AUTH_RETRY and timeout defined by MESH_AUTH_TIMEOUT.
Ignoring the sending of reply message on "SAE confirm before commit"
to avoid "ping-pong" issues with other mesh nodes. This is obvious when
number of mesh nodes in MBSS reaching 6.
Signed-off-by: Chun-Yeow Yeoh <yeohchunyeow@gmail.com>
Signed-off-by: Bob Copeland <me@bobcopeland.com>
The mesh peering manager establishes and maintains links among
mesh peers, tracking each peer link via a finite state machine.
This implementation supports open mesh peerings.
[assorted fixes from Yu Niiro <yu.niiro@gmail.com>]
[more fixes from Masashi Honma <masashi.honma@gmail.com>]
Signed-off-by: Javier Lopez <jlopex@gmail.com>
Signed-off-by: Javier Cardona <javier@cozybit.com>
Signed-off-by: Ashok Nagarajan <ashok.dragon@gmail.com>
Signed-off-by: Jason Mobarak <x@jason.mobarak.name>
Signed-hostap: Bob Copeland <me@bobcopeland.com>