Commit graph

2671 commits

Author SHA1 Message Date
Jouni Malinen
e30de6c250 tests: sigma_dut OWE with invalid DH Param element
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-10-10 18:35:19 +03:00
Jouni Malinen
25fdb2756c tests: Opportunistic Wireless Encryption and unsupported group
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-10-10 18:27:58 +03:00
Jouni Malinen
2e37b5fbe7 tests: Remove op_cl and ch_list from DPP
These were removed from the protocol.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-10-10 01:34:49 +03:00
Jouni Malinen
22a0147557 tests: Remove DPP C-sign-key expiry testing
This was removed from the protocol.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-10-10 01:19:22 +03:00
Jouni Malinen
b9c0e1fa5c tests: sigma_dut with OWE
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-10-09 16:54:03 +03:00
Jouni Malinen
872d0f93cc tests: Opportunistic Wireless Encryption transition mode (multi BSS)
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-10-09 13:39:23 +03:00
Jouni Malinen
89baf47104 tests: OWE using cfg80211 connect command
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-10-09 12:39:14 +03:00
Jouni Malinen
26b96d050d tests: Opportunistic Wireless Encryption and PMKSA caching
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-10-09 12:12:54 +03:00
Jouni Malinen
8acde197c2 tests: OWE DH groups
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-10-08 17:12:35 +03:00
Jouni Malinen
4361ab0108 tests: OWE Transition Mode
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-10-08 17:12:35 +03:00
Jouni Malinen
e0e1fde8a8 tests: P2P GO with Interworking element
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-10-05 14:54:15 +03:00
Jouni Malinen
002b49ed07 tests: sigma_dut Suite B station with RSA certificate
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-10-03 18:16:51 +03:00
Jouni Malinen
0ba13e8613 tests: Update server and user certificates (2017)
The previous versions expired, so need to re-sign these to fix number of
the EAP test cases. In addition, add a shell script (update.sh) and the
needed CA files to automate this full update process.

Signed-off-by: Jouni Malinen <j@w1.fi>
2017-10-01 18:47:02 +03:00
Jouni Malinen
8cfdca1266 tests: sigma_dut PMF group management cipher selection on STA
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-26 17:54:56 +03:00
Jouni Malinen
53041e75d2 tests: PMF group mgmt cipher constraints
Verify new wpa_supplicant group_mgmt parameter functionality.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-26 17:40:02 +03:00
Jouni Malinen
61a56c1480 Add group_mgmt network parameter for PMF cipher selection
The new wpa_supplicant network parameter group_mgmt can be used to
specify which group management ciphers (AES-128-CMAC, BIP-GMAC-128,
BIP-GMAC-256, BIP-CMAC-256) are allowed for the network. If not
specified, the current behavior is maintained (i.e., follow what the AP
advertises). The parameter can list multiple space separate ciphers.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-26 17:40:02 +03:00
Jouni Malinen
f41f04d04c tests: Make dbus_scan_abort more robust
There was a race condition on the sequence where iface.AbortScan() is
immediately followed by iface.Scan(). If the driver event
(NL80211_CMD_SCAN_ABORTED) arrived after the following new scan request,
the D-Bus operation failed. This is not what this test case is trying to
check, so wait for an indication of the previous scan having terminated
properly before issuing the next scan.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-20 15:37:58 +03:00
Jouni Malinen
78b6be046d tests: Suite B with RSA keys
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-18 12:12:48 +03:00
Jouni Malinen
2ef00a364b tests: sigma_dut with Suite B
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-15 00:38:21 +03:00
Jouni Malinen
53d7f351f4 tests: FILS SK with PFS and PMKSA caching
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-13 22:17:58 +03:00
Jouni Malinen
f4ad8412b4 tests: RSN pre-authentication based on pre-connection scan results
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-12 16:47:30 +03:00
Andrei Otcheretianski
ae503866b9 tests: Fix radius_acct_failure_sta_data test
The STA can get disconnected event before the AP processed the
deauthentication frame, resulting in GET_FAIL command being sent too
early. Fix this by waiting for AP-STA-DISCONNECTED on AP side, too.

Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
2017-09-10 22:05:33 +03:00
Aloni, Adiel
8031003fec tests: Use global control interface in autogo_m2d test
If dedicated P2P device is used, SET p2p_no_group_iface 0 should be
directed to the P2P device.

Signed-off-by: Adiel Aloni <adiel.aloni@intel.com>
2017-09-10 22:03:54 +03:00
Li Zhijian
783bf87144 tests: Fix missing function on some rrm test case error paths
Import vht_supported from test_ap_vht to fix the following issue:

rrm_beacon_req_table_vht run failed: global name 'vht_supported' is not defined

Signed-off-by: Li Zhijian <lizhijian@cn.fujitsu.com>
2017-09-10 21:54:38 +03:00
Li Zhijian
b62d0544c5 tests: Enable D-Bus test on more platforms
Not all distro contains /var/run/dbus/pid, debian for example:
dbus-daemon start with nopidfile
root@debian9:/home/lizhijian/chroot_clean/tmp/build-hwsim/hostap/tests/hwsim# ps aux |grep dbus
message+   598  0.0  0.1  46068  4836 ?        Ss   15:46   0:00 /usr/bin/dbus-daemon --system --address=systemd: --nofork --nopidfile --systemd-activation
Debian-+   656  0.0  0.0  45220  3924 ?        Ss   15:46   0:00 /usr/bin/dbus-daemon --session --address=systemd: --nofork --nopidfile --systemd-activation

Signed-off-by: Li Zhijian <lizhijian@cn.fujitsu.com>
Signed-off-by: Xiaodong Jia <jiaxd-fnst@cn.fujitsu.com>
2017-09-10 21:52:54 +03:00
Jouni Malinen
b99d62c735 tests: Remove forgotten print from ap_wpa2_eap_sim_zero_db_timeout
This was supposed to be used during development testing only.

Signed-off-by: Jouni Malinen <j@w1.fi>
2017-09-10 02:15:05 +03:00
Jouni Malinen
c25aada9ec tests: EAP-AKA' with external UMTS auth to hit Synchronization-Failure
Signed-off-by: Jouni Malinen <j@w1.fi>
2017-09-10 01:39:37 +03:00
Jouni Malinen
504c7ffd69 tests: D-Bus mesh signals and properties
Signed-off-by: Jouni Malinen <j@w1.fi>
2017-09-10 01:39:37 +03:00
Jouni Malinen
29087dec9f tests: Enable DPP in default configuration files
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-06 21:21:56 +03:00
Jouni Malinen
cc8330b88b tests: Write MSK dump files from authentication server
This makes it easier to post-process frame capture files if frames need
to be decrypted in test cases that do not configure wlantest with the
PMK directly (i.e., mainly the cases when a RADIUS server is used).

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-05 19:29:01 +03:00
Jouni Malinen
eea62048d8 tests: SAE commit message override on wpa_supplicant
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-04 13:32:04 +03:00
Jouni Malinen
cd06e2663b tests: SAE commit message override on hostapd
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-04 13:32:03 +03:00
Jouni Malinen
1342c47a33 tests: SAE reflection attack using internal hostapd mechanism
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-09-04 13:32:03 +03:00
Jouni Malinen
bbb42bf091 tests: Verify data connectivity with DPP AKM
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-08-24 23:47:58 +03:00
Jouni Malinen
ee8ef9cacf tests: DPP association with nl80211 connect command
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-08-24 23:31:46 +03:00
Jouni Malinen
b62c948a26 tests: Make dpp_qr_code_auth_initiator_enrollee more robust
Wait for the configuration step to complete before forcefully
terminating DPP listen. Previous version was causing failures for this
test case sequence:
dpp_qr_code_auth_initiator_enrollee dpp_pkex_config2

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-08-23 15:55:46 +03:00
Jouni Malinen
96fa53f911 tests: Update DPP discovery override value format
This changed in the DPP tech spec, so update the test case to match the
current encoding.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-08-23 00:31:30 +03:00
Jouni Malinen
d1888b142e tests: Remove use of dpp_devices_override
The devices object was removed, so this parameter will disappear as
well.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-08-22 23:45:46 +03:00
Jouni Malinen
1ed508d9ea tests: sigma_dut tests for SAE
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-08-22 21:23:04 +03:00
Jouni Malinen
d33222d1fe tests: hostapd with zero length ap_pin parameter
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-08-18 21:10:52 +03:00
Andrei Otcheretianski
9a6e2a5ede tests: Make wnm_bss_tm_req_with_mbo_ie more robust
On slow machines or inside VM it may take some time for "DISCONNECTED"
event to arrive. Since the retry delay counter is started already, it
may result in less than 5 seconds time between "DISCONNECTED" and
"CONNECTED" events.

Fix the test by taking more accurate timestamps between the events.

Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
2017-07-18 13:29:07 +03:00
Andrei Otcheretianski
cdb3aab569 tests: Fix RRM tests to allow refused/incapable responses
Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
2017-07-17 18:04:00 +03:00
Jouni Malinen
d557183150 tests: Rejection of group-addressed RRM measurement request
Signed-off-by: Jouni Malinen <j@w1.fi>
2017-07-17 17:47:25 +03:00
Jouni Malinen
c1361765fd tests: Additional EAP-TTLS error path
This is a regression test for a memory leak on an error path.

Signed-off-by: Jouni Malinen <j@w1.fi>
2017-07-08 16:21:38 +03:00
Jouni Malinen
e4e99927bf tests: Additional LEAP error path
This is a regression test for a memory leak on an error path.

Signed-off-by: Jouni Malinen <j@w1.fi>
2017-07-08 16:14:03 +03:00
Adiel Aloni
0b6cbc4e64 tests: Use global control interface in test_p2p_channel.py
Previously p2p_channel_drv_pref_* tests would fail
if dedicated P2P device is used, since the SET commands
were sent to incorrect interface.
Fix this by using a global control interface instead.

Signed-off-by: Adiel Aloni <adiel.aloni@intel.com>
2017-07-08 16:06:38 +03:00
Johannes Berg
100d334f43 tests: Print higher debug level on console
We capture the dmesg that contains everything, but if a test
causes a kernel crash we will miss all logging at higher levels
like debug. Change the printk level to catch all of that too.

Signed-off-by: Johannes Berg <johannes.berg@intel.com>
2017-07-08 15:19:24 +03:00
Johannes Berg
a95d5fdbe1 tests: Catch various lockdep warnings
Lockdep no longer prints "INFO:" but now prints "WARNING:".
Also add the "*** DEADLOCK ***" string it usually prints so
if it changes again we can keep finding that string.

Signed-off-by: Johannes Berg <johannes.berg@intel.com>
2017-07-08 15:18:40 +03:00
Andrei Otcheretianski
4874f5bad3 tests: Skip dpp_pkex_config dpp_pkex_config2 tests correctly
When CONFIG_DPP is not defined these tests would fail. Skip them.

Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
2017-07-07 23:37:13 +03:00
Vidyullatha Kanchanapally
9d3eb21ec4 tests: FILS ERP authentication followed by PMKSA caching
This test case verifies that both wpa_supplicant and hostapd are adding
a PMKSA cache entry based on FILS shared key authentication using ERP.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-07-05 17:55:33 +03:00