Commit graph

24 commits

Author SHA1 Message Date
Jouni Malinen
cc0a04ac86 tests: Split mbo_supp_oper_classes into multiple test cases
In addition, add even more workarounds for cfg80211 regulatory state
clearing since this test case seems to be the most likely one to fail
due to country=98 issues.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-01-05 00:21:41 +02:00
Jouni Malinen
99bc57d0d1 tests: Fix mbo_supp_oper_classes after cfg80211 change
The Linux kernel commit 113f3aaa81bd ("cfg80211: Prevent regulatory
restore during STA disconnect in concurrent interfaces") broke the
regulatory clearing attempt in this test case since
cfg80211_is_all_idle() is now returning false due to the AP interface
being up and that results in the Country IE -based regulatory
information not getting cleared back to defaults.

Work around this by stopping the AP interface first so that when the
station interface receives the disconnection, there are no other active
interfaces in the system. In addition, wait for REGDOM event for the
Country IE hint after association to avoid disconnection before the
regulatory events have been fully processed.

Signed-off-by: Jouni Malinen <j@w1.fi>
2018-12-22 16:13:14 +02:00
Jouni Malinen
db856f47ef tests: Fix mbo_supp_oper_classes with new regdb
Change country code KZ to SY for the 2.4 GHz only case since 5 GHz rules
were added for KZ.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-06-20 15:23:50 +03:00
Jouni Malinen
5d9fa5ead2 tests: MBO ANQP
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-03-10 18:59:12 +02:00
Jouni Malinen
9302b87486 tests: MBO and WPA2 without PMF
Signed-off-by: Jouni Malinen <j@w1.fi>
2016-12-27 11:16:51 +02:00
Jouni Malinen
62066bef69 tests: MBO and ignoring disallowed association
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2016-09-25 17:31:26 +03:00
Jouni Malinen
f75a0c0c0c tests: Fix a typo in a debug message (mbo_assoc_disallow)
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2016-09-25 17:31:26 +03:00
Jouni Malinen
80b84fb2d2 tests: Update MBO test cases for non_pref_chan changes
The reason_detail field was removed from the implementation, so the test
cases need matching changes.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2016-09-25 17:31:26 +03:00
Jouni Malinen
cb320a6d2d tests: Allow regdb missing some op classes in mbo_supp_oper_classes
Not all installed regdb files include channels for global operating
classes 121-123, and 129.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2016-08-22 19:22:01 +03:00
Jouni Malinen
bc6e32880f tests: Remove extra semicolons from python scripts
Signed-off-by: Jouni Malinen <j@w1.fi>
2016-07-03 22:37:01 +03:00
Jouni Malinen
a8fd58aa42 tests: MBO and supported operating classes
Signed-off-by: Jouni Malinen <j@w1.fi>
2016-07-03 19:13:41 +03:00
Jouni Malinen
b47a743942 tests: MBO BSS transition request MBO IE parsing
Signed-off-by: Jouni Malinen <j@w1.fi>
2016-07-01 01:13:54 +03:00
Jouni Malinen
0073f453ff tests: MBO failure cases
Signed-off-by: Jouni Malinen <j@w1.fi>
2016-06-30 12:53:05 +03:00
Jouni Malinen
3e3f1602b5 tests: MBO WNM token wrap around
Signed-off-by: Jouni Malinen <j@w1.fi>
2016-06-30 12:53:05 +03:00
Jouni Malinen
bbd41e4d2b tests: Invalid MBO non_pref_chan values
Signed-off-by: Jouni Malinen <j@w1.fi>
2016-06-30 01:13:16 +03:00
Jouni Malinen
b9dca2a954 tests: MBO mbo_cell_capa duplicate update
Signed-off-by: Jouni Malinen <j@w1.fi>
2016-06-30 00:34:48 +03:00
Jonathan Afek
9fd6804d61 tests: Mark 525 tests as remote compatible
After successfully passing the 525 tests on a remote setup mark the
tests as remote compatible.

Signed-off-by: Jonathan Afek <jonathanx.afek@intel.com>
2016-06-27 21:47:37 +03:00
Jouni Malinen
0663ae22ff tests: Do not use tabs for indentation
Be more consistent with indentation (always uses spaces in Python
files).

Signed-off-by: Jouni Malinen <j@w1.fi>
2016-04-25 00:19:40 +03:00
Janusz Dziedzic
8b8a1864ff tests: Pass full apdev to add_ap() function (1)
Pass the full apdev to the add_ap() function instead of just ifname.
This allows us to handle also remote hosts while we can check
apdev['hostname'], apdev['port'].

This step (1) converts the cases where apdev[#]['ifname'] was used as
the argument to hostapd.add_ap().

Signed-off-by: Janusz Dziedzic <janusz.dziedzic@tieto.com>
2016-04-03 22:45:57 +03:00
Jouni Malinen
452874a9df tests: MBO STA supported operating classes
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2016-02-24 12:31:09 +02:00
Jouni Malinen
46185f5bfd tests: MBO non-preferred channel list
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2016-02-22 21:17:38 +02:00
Jouni Malinen
85c7ea9b48 tests: MBO cellular data capability update with PMF required
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2016-02-22 19:53:05 +02:00
Jouni Malinen
c321652934 tests: MBO cellular data capability update
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2016-02-22 19:53:05 +02:00
Avraham Stern
6605562af6 tests: MBO association disallowed indication
Add a test that verifies that no Association Request frame is sent to
APs that include the MBO IE with association disallowed attribute in
Beacon and Probe Response frames.

Signed-off-by: Avraham Stern <avraham.stern@intel.com>
2016-02-22 19:53:04 +02:00