The Linux kernel commit 113f3aaa81bd ("cfg80211: Prevent regulatory
restore during STA disconnect in concurrent interfaces") broke the
regulatory clearing attempt in this test case since
cfg80211_is_all_idle() is now returning false due to the AP interface
being up and that results in the Country IE -based regulatory
information not getting cleared back to defaults.
Work around this by stopping the AP interface first so that when the
station interface receives the disconnection, there are no other active
interfaces in the system. In addition, wait for REGDOM event for the
Country IE hint after association to avoid disconnection before the
regulatory events have been fully processed.
Signed-off-by: Jouni Malinen <j@w1.fi>
The reason_detail field was removed from the implementation, so the test
cases need matching changes.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
After successfully passing the 525 tests on a remote setup mark the
tests as remote compatible.
Signed-off-by: Jonathan Afek <jonathanx.afek@intel.com>
Pass the full apdev to the add_ap() function instead of just ifname.
This allows us to handle also remote hosts while we can check
apdev['hostname'], apdev['port'].
This step (1) converts the cases where apdev[#]['ifname'] was used as
the argument to hostapd.add_ap().
Signed-off-by: Janusz Dziedzic <janusz.dziedzic@tieto.com>
Add a test that verifies that no Association Request frame is sent to
APs that include the MBO IE with association disallowed attribute in
Beacon and Probe Response frames.
Signed-off-by: Avraham Stern <avraham.stern@intel.com>