It is possible that a P2P GO has been discovered through a non-P2P scan
that did not return P2P IE in Probe Response frames. To cover those
cases, check also Beacon frame (if received) for P2P IE.
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
If the AP (P2P GO) has changes its channel of SSID recently, the BSS
table may have multiple entries for a BSSID. Select the one which was
most recently updated for WPS/P2P operations in such case to increase
the likelihood of using current information.
Signed-hostap: Jouni Malinen <j@w1.fi>
For various P2P use cases, it is useful to have more accurate timestamp
for the peer information update. This commit improves scan result
handling by using a single timestamp that is taken immediately after
fetching the results from the driver and then using that value to
calculate the time when the driver last updated the BSS entry. In
addition, more debug information is added for P2P peer updates to be
able to clearly see how old information is being used here.
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
The RANGE=N1-N2 command did not return any entries in some cases where
N1 does not match with any BSS entry. Fix this by allow entries to be
fetched even without knowing the exact id values.
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
When ANQP_GET or HS20_ANQP_GET is used to request ANQP information,
unshare the ANQP information (i.e., create a per-BSS copy of it) to
make sure the information from the specified BSS is available in case
the APs provide different information within HESSID.
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
This is an initial step in allowing the ANQP responses to be shared
among multiple BSSes if the BSSes are determined to be operating under
identical configuration.
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
"BSS p2p_dev_addr=<P2P Device Address>" can now be used to fetch a
specific BSS entry based on the P2P Device Address of the GO to avoid
having to iterate through the full BSS table when an external program
needs to figure out whether a specific peer is currently operating as
a GO.
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
Add mechanism for using GAS/ANQP to query Interworking related
information from APs. The received information is stored in the BSS
table and can be viewed with ctrl_iface BSS command.
New ctrl_iface command ANQP_GET can be used to fetch ANQP elements from
a specific AP. Additional commands FETCH_ANQP and STOP_FETCH_ANQP can be
used to initiate and stop an iteration through all APs in the BSS table
that indicate support Interworking to fetch ANQP elements from them.
Add an "Interface.FlushBSS" method to the new D-Bus API and a "flush"
method to the old API. Both take an age parameter that is a threshold
(in seconds) for selecting entries to evict. Setting this parameter
to zero flushes all entries from the cache.
This mechanism is useful for a connection manager to clear state at
startup and on resume (where the age parameter may be used to hold
onto recent/valid data).
This allows the driver wrappers to return two sets of IEs, so that
the BSS code can use information from both Beacon and Probe Response
frames if needed. For example, some Cisco APs seem to include more
information in Wireless Provisioning Services IE when it is in the
Beacon frame.
Get more information about scans when updating BSS table information.
This allows the missing-from-scans expiration rule to work properly
when only partial set of channels or SSIDs are being scanned.
This allows the BSS list to be iterated in order of increasing id
to avoid problems with new scans reordering entries. The order on the
wpa_s->bss list changes with most recently updated entries being moved
to the tail of the list while wpa_s->bss_id list maintains its order
with new entries being added to the tail and old entries being removed
when they expire.
Collect information from scan results into a BSS table that will not
expire information as quickly as scan results where every new scan,
no matter for how limited set of channels/SSIDs, clears all old
information.
For now, this is only used for D-Bus BSS added/removed notifications,
but this will likely be extended to be used internally instead of the
scan results to better support partial scans.