Since 3bdc651a62, start.sh creates the logs/current symlink even if
LOGDIR was set in the environment, as is the case when using run-all.sh.
However, run-all.sh and start.sh use a separate 'date' invocation so the
resulting string may be different. Usually it is the same because the
two invocations immediately follow each other, *except* if run-all.sh
also does a build. In addition, if the user sets LOGDIR to something
else, the symlink is completely bogus.
Fix this by not relying on the 'date' invocation for creating the
symlink. Instead, use the basename of LOGDIR. To keep things consistent
with current behavior, only create the symlink if LOGDIR points to a
subdirectory of DIR/logs.
The following use cases now work reliably:
* run-all.sh with or without the -B option;
* manually calling start.sh followed by run-tests.py without setting
LOGDIR.
* manually calling start.sh with LOGDIR set to a subdirectory of logs
and calling run-tests.py without --logdir option (which makes it
default to logs/current).
* run-all.sh with LOGDIR set to a subdirectory of logs.
Signed-off-by: Arnout Vandecappelle (Essensium/Mind) <arnout@mind.be>
This is in preparation for an implementation change that results in this
unreachable server case not incrementing radiusAuthClientAccessRequests.
Signed-off-by: Jouni Malinen <j@w1.fi>
These checks were repeated in almost every test case, so use helper
functions to get rid of duplicated (copy-pasted) code.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add even more workarounds for cfg80211 regulatory state clearing since
these DFS test cases seem to be the most likely ones to fail due to
country=98 issues.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add even more workarounds for cfg80211 regulatory state clearing since
these DFS test cases seem to be the most likely ones to fail due to
country=98 issues.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add even more workarounds for cfg80211 regulatory state clearing since
these WNM test cases seem to be the most likely ones to fail due to
country=98 issues.
Signed-off-by: Jouni Malinen <j@w1.fi>
In addition, add even more workarounds for cfg80211 regulatory state
clearing since this test case seems to be the most likely one to fail
due to country=98 issues.
Signed-off-by: Jouni Malinen <j@w1.fi>
This is a regression test case for FT-over-DS that got broken on
mac80211-based drivers when the extra key reinstallation checks were
added.
Signed-off-by: Jouni Malinen <j@w1.fi>
ap_ft_oom seemed to depend on undesired wpa_supplicant behavior of
trying to do FT protocol even without being ready for reassociation.
This is going to be fixed in wpa_supplicant which would make this test
case fail, so split it into separate test cases for each failure item to
be able to avoid incorrect test failures.
Signed-off-by: Jouni Malinen <j@w1.fi>
The previous roam() and roam_over_ds() checks would have ignored failing
association rejection if a consecutive attempt to connect succeeds
within the initial time limit. This can miss incorrect behavior, so
check explicitly for association rejection.
Signed-off-by: Jouni Malinen <j@w1.fi>
The number of direct allocation within wpa_supplicant_mesh_init()
has been reduced due to RSN init function is factored out.
Signed-off-by: Peter Oh <peter.oh@bowerswilkins.com>
Verify that the beacon report contains the last beacon report
indication subelement when requested in the beacon request.
Signed-off-by: Avraham Stern <avraham.stern@intel.com>
Verify that when the frame body subelement causes the
measurement report element to exceed the maximum element size,
the beacon report is fragmented and the frame body fragment ID
subelement is added with the correct fragment number.
Signed-off-by: Avraham Stern <avraham.stern@intel.com>
Verify that not updating GTK (i.e., only update PTK) in the driver does
not break connectivity. This case is different after the check for
"already in-use GTK" and rejection of GTK reinstallation.
Signed-off-by: Jouni Malinen <j@w1.fi>
Use of country=00 (world roaming) seemed to not work anymore with the
current cfg80211 regulatory implementation since the existing channel is
left enabled when moving to country=00. Use a specific country code that
does enforce the selected channel from being used anymore to make this
test case pass again.
The change in cfg80211 behavior is from the kernel commit 113f3aaa81bd
("cfg80211: Prevent regulatory restore during STA disconnect in
concurrent interfaces").
Signed-off-by: Jouni Malinen <j@w1.fi>
With this command, RSSI signal can be controlled. Due to restrictions in
kernel, only values in the range of [-30, -50] can be used. The command
is implemented by changing the TX power.
Signed-off-by: Beni Lev <beni.lev@intel.com>
It was possible for the 5 GHz PKEX channels to be enabled, e.g., when
running "ap_ht40_csa2 dpp_pkex_no_responder" test sequence, and that
resulted in a failure in dpp_pkex_no_responder due to the unexpectedly
long wait needed for the DPP-FAIL event. Increase the wait time to allow
for 5 GHz PKEX channels to be probed.
Signed-off-by: Jouni Malinen <j@w1.fi>
This allows more accurate logging of failures related to the cfg80211
country=98 (intersection) case. This version is trying to give some more
time to allow the country code to clear, but that does not seem to be
sufficient with the current cfg80211 implementation for country=98 (but
might be for other cases).
The additional check for country=98 at the beginning of each test case
is an attempt to force cfg80211 to restore world roaming state with a
new association and disconnection at the station side detected after the
AP side has already stopped. This is needed after the Linux kernel
commit 113f3aaa81bd ("cfg80211: Prevent regulatory restore during STA
disconnect in concurrent interfaces").
Signed-off-by: Jouni Malinen <j@w1.fi>
This is needed to avoid leaving unexpected cfg80211 regulatory country
code in place at the point when a test case terminates.
Signed-off-by: Jouni Malinen <j@w1.fi>
Previously, the special value 0 was used to indicate no UDP checksum.
Replace that with the calculated checksum for more like use case.
Signed-off-by: Jouni Malinen <j@w1.fi>
The ap_open_tdls_vht* test cases could leave some pending regulatory
Beacon hints waiting to be cleared during the following test case. This
would result in a failure if the following test case expected specific
regdom event behavior. For example, this caused "ap_open_tdls_vht160
dbus_country" sequence to result in failure in dbus_country. Fix this by
using more robust sequence in clearing regdom state at the end of the
TDLS test cases that have the AP advertising a country code.
Signed-off-by: Jouni Malinen <j@w1.fi>