When going through 4-way handshake, the station side reports
CTRL-EVENT-CONNECTED after having sent out EAPOL-Key msg 4/4. The AP
side reports AP-STA-CONNECT after having completed processing of this
frame. Especially when using UML with time travel, it is possible for
the connectivity test to be started before the AP side has configured
the pairwise TK if the test is triggered based on CTRL-EVENT-CONNECTED
instead of AP-STA-CONNECT.
Add explicit wait for AP-STA-CONNECT in some of these cases to reduce
likelihood of reporting failures for test cases that are actually
behaving as expected. This shows up with "dev1->dev2 unicast data
delivery failed" in the test log.
Do the same before requesting reauthentication from the station side
since that has a similar issue with the EAPOL-Start frame getting
encrypted before the AP is ready for it.
Signed-off-by: Jouni Malinen <j@w1.fi>
Pass the full apdev to the add_ap() function instead of just ifname.
This allows us to handle also remote hosts while we can check
apdev['hostname'], apdev['port'].
This step (1) converts the cases where apdev[#]['ifname'] was used as
the argument to hostapd.add_ap().
Signed-off-by: Janusz Dziedzic <janusz.dziedzic@tieto.com>
run-tests.py is running as root, so sudo does not need to be used
anymore from within each test case.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
This makes it easier to replace data connectivity testing to use
something else than local hwsim_test binary on the controller device.
Signed-off-by: Jouni Malinen <j@w1.fi>
Only run-tests.py is actually executed, so there is no need to specify
the interpreter in all the helper files and test script files.
Signed-off-by: Jouni Malinen <j@w1.fi>