This likely passes today (at least without ASAN), but without the next
commit, it trips up a use-after-free bug, which ASAN can catch.
So consider this a regression test.
Signed-off-by: Brian Norris <briannorris@chromium.org>
Remove this part of the dbus_network test case since it would be causing
failures after wpa_supplicant is modified to accept empty strings
through D-Bus.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This makes it more convenient to run tests with builds that disable
TKIP/WPA(v1) support completely.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
dbus_p2p_go_neg_init, dbus_p2p_group_idle_timeout, and
dbus_p2p_group_termination_by_go could end up print a "DETACH failed"
exception as a warning from WpaSupplicant.__del__ for the dev1 instance
used within the TestDbusP2p class. This did not cause the test cases to
fail, but the output is a bit confusing, so clean this up be explicitly
closing the control interface monitor sockets and furthermore by
ignoring the "DETACH failed" exception within __del__.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Use struct.unpack() to get a list of int and then generate a list of
hexstr octets from it for ':'.join() to get consistent behavior for both
python2 and python3.
Signed-off-by: Jouni Malinen <j@w1.fi>
This is needed in cases the hexlify() output is used to concatenate with
a string or used in string comparisons.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Signed-off-by: Jouni Malinen <j@w1.fi>
Based on Jouni Malinen's [76055b4c6 "tests: D-Bus Get/Set Pmf"], modified
to use the correct "s" signature for the "Pmf" property.
Removed the negative test cases, because the synthesized property doens't
seem to do error checking upon being set.
Signed-off-by: Jouni Malinen <j@w1.fi>
Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>
Clear the model_name parameter back to the default (empty string) at the
beginning and the end of dbus_set_global_properties to avoid failures if
the test case is run multiple times.
Signed-off-by: Jouni Malinen <j@w1.fi>
Ignore any unexpected deviceLost event before the peer devices has been
discovered. This works around issues where the previous test case
terminates before the D-Bus events have been fully delivered. This could
happen, e.g., when running dbus_p2p_discovery twice in a row.
Signed-off-by: Jouni Malinen <j@w1.fi>
There was a race condition on the sequence where iface.AbortScan() is
immediately followed by iface.Scan(). If the driver event
(NL80211_CMD_SCAN_ABORTED) arrived after the following new scan request,
the D-Bus operation failed. This is not what this test case is trying to
check, so wait for an indication of the previous scan having terminated
properly before issuing the next scan.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
It was apparently possible to get a propertiesChanged event from an
earlier test case with an empty Groups property. That ended up this case
exiting immediately before running through the steps and consequently,
failing due to missed operations. Make this less likely to happen by
accepting the Groups property emptying event only after a group has been
added for a peer first.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
Pass the full apdev to the add_ap() function instead of just ifname.
This allows us to handle also remote hosts while we can check
apdev['hostname'], apdev['port'].
This step (4) converts the cases that call hostapd.add_ap() from a
helper function that got apdev[i] as an argument.
Signed-off-by: Janusz Dziedzic <janusz.dziedzic@tieto.com>
Pass the full apdev to the add_ap() function instead of just ifname.
This allows us to handle also remote hosts while we can check
apdev['hostname'], apdev['port'].
This step (1) converts the cases where apdev[#]['ifname'] was used as
the argument to hostapd.add_ap().
Signed-off-by: Janusz Dziedzic <janusz.dziedzic@tieto.com>
init=CORE was previously used due to invalid db.txt data for 00. For
now, allow both it and the new init=USER after fixed db.txt.
Signed-off-by: Jouni Malinen <j@w1.fi>
It was possible for the BSSs object property change signal to be
generated during the OOM test case for Get(). If that happened, the
signal was not sent out, but the following Get(BSSs) operation succeeded
unexpectedly which resulted in a test failure. Make this less likely to
happen by waiting 50 ms between the scan and Get(BSSs) operation. This
should be sufficient to cover most cases since wpa_supplicant uses 5 ms
timeout for D-Bus property changed updates.
Signed-off-by: Jouni Malinen <j@w1.fi>
This test case fails with the current internal TLS client implementation
since the needed altsubject_match parameter is not yet supported.
Signed-off-by: Jouni Malinen <j@w1.fi>
This test case was failing if a PropertiesChanged signal for P2P peer
gets delivered from a previous test case. Avoid that by waiting for the
new group to be formed before processing any PropertiesChanged signals.
This failure was triggered by the following test case sequence:
dbus_p2p_two_groups dbus_p2p_group_idle_timeout
Signed-off-by: Jouni Malinen <j@w1.fi>
This is needed since the forced OOM may have forced the cached
information to be invalid or dropped. This issue was hit with the
following hwsim test case sequence:
ap_interworking_scan_filtering fst_sta_config_llt_large dbus_connect_oom
wpas_ctrl_enable_disable_network
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>