HE: Fix HE capability check for PPE threshold present

The the mask for PPE threshold present in the HE phy capability byte 6 is
0x80 and not 0x6. This incorrect mask breaks the length calculation and as
result the acceptance of the HE capabilities for STAs which either:

* don't have the PPE threshold present bit set AND the Codebook Size={7,5}
  MU Feedback or the Triggered SU Beamforming feedback bit set

* do have the PPE threshold present set AND neither the Codebook Size={7,5}
  MU Feedback nor the Triggered SU Beamforming feedback bit set

Fixes: 8f5fc369e2 ("HE: Fix HE Capabilities element variable length encoding")
Signed-off-by: Sven Eckelmann <seckelmann@datto.com>
This commit is contained in:
Sven Eckelmann 2019-06-13 01:10:07 +02:00 committed by Jouni Malinen
parent e1e203c800
commit 29f8556189

View file

@ -23,7 +23,7 @@ static u8 ieee80211_he_ppet_size(u8 ppe_thres_hdr, const u8 *phy_cap_info)
u8 sz = 0, ru; u8 sz = 0, ru;
if ((phy_cap_info[HE_PHYCAP_PPE_THRESHOLD_PRESENT_IDX] & if ((phy_cap_info[HE_PHYCAP_PPE_THRESHOLD_PRESENT_IDX] &
HE_PHYCAP_PPE_THRESHOLD_PRESENT_IDX) == 0) HE_PHYCAP_PPE_THRESHOLD_PRESENT) == 0)
return 0; return 0;
ru = (ppe_thres_hdr >> HE_PPE_THRES_RU_INDEX_BITMASK_SHIFT) & ru = (ppe_thres_hdr >> HE_PPE_THRES_RU_INDEX_BITMASK_SHIFT) &