ansible/roles/prometheus_snmp/files/mibs/XUPS-MIB.txt

2751 lines
98 KiB
Text
Raw Normal View History

2023-11-04 21:36:27 +01:00
XUPS-MIB DEFINITIONS ::= BEGIN
IMPORTS
TimeTicks, Gauge32, Counter32, Integer32
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
sysName
FROM RFC1213-MIB
eaton, xupsEnvironment
FROM EATON-OIDS
-- Need to import these EMP objects to support PowerMIB-style traps for EMP
xupsContactIndex, xupsContactType, xupsContactState, xupsContactDescr,
xupsEnvRemoteTemp, xupsEnvRemoteTempLowerLimit, xupsEnvRemoteTempUpperLimit,
xupsEnvRemoteHumidity, xupsEnvRemoteHumidityLowerLimit,
xupsEnvRemoteHumidityUpperLimit, xupsEnvRemoteCommunicationStatus
FROM EATON-EMP-MIB;
xupsMIB MODULE-IDENTITY
LAST-UPDATED "202005270000Z"
ORGANIZATION "Eaton Corporation"
CONTACT-INFO
"Eaton Power Quality Technical Support (PQTS) group
www.eaton.com/powerxpert
Technical Resource Center phone numbers
United States: 1.800.843.9433 or 919.870.3028
Canada: 1.800.461.9166 ext. 260
All other countries: Call your local service representative."
DESCRIPTION
"Defines Eaton's proprietary PowerMIB for UPS and
related device data.
Copyright (C) Exide Electronics 1992-98
Copyright (C) Powerware Corporation 1999-2004
Copyright (C) Eaton Corporation (2005-)."
REVISION "202005270000Z"
DESCRIPTION
"xupsEnvRemoteCommunicationStatus is added, it reports the EMP communication status.
Add a new value in enum xupsOutputStatus for the case the output is powered but no continuity feature."
REVISION "202001230000Z"
DESCRIPTION
"xupsInputTable, xupsOutputTable and xupsBypassTable collection are
completed with the phase to phase voltage measure."
REVISION "201909270000Z"
DESCRIPTION
"xupsOutputSource data can monitor the ESS mode."
REVISION "201909120000Z"
DESCRIPTION
"Provide new data that reflects some battery alarm : xupsBatteryFailure,
xupsBatteryNotPresent, xupsBatteryAged, xupsBatteryLowCapacity."
REVISION "201909100000Z"
DESCRIPTION
"Change the data xupsBatteryLastReplacedDate to read-only because the card
sets it automatically when the battery replacement is detected."
REVISION "201904120000Z"
DESCRIPTION
"Provide the status of the main AC Input in xupsInputStatus.
Provide the status of the AC Output in xupsOutputStatus and a new trap
and alarm 'load not protected' in xupsOutputNotProtected."
REVISION "201903050000Z"
DESCRIPTION
"Provide more UPS identification data as xupsIdentPartNumber and xupsIdentSerialNumber.
Provide a collection xupsAgent that contains identification data of the card :
xupsAgentManufacturer, xupsAgentModel, xupsAgentSoftwareVersion, xupsAgentPartNumber,
xupsAgentSerialNumber"
REVISION "201902190000Z"
DESCRIPTION
"To ensure consistency whith the measures done on the UPS, the data following are renamed :
xupsInputAverageCurrent to xupsInputTotalCurrent,
xupsOutputAverageCurrent to xupsOutputTotalCurrent,
xupsBypassAverageCurrent to xupsBypassTotalCurrent."
REVISION "201809120000Z"
DESCRIPTION
"Add new data xupsInputId, xupsInputName, xupsInputCurrentHighPrecision in the table xupsInputTable.
Add new sub collection xupsInputTotal with xupsInputAverageVoltage, xupsInputAverageCurrent,
xupsInputTotalWatts, xupsInputTotalVA, xupsInputAveragePowerFactor inside.
Add new data xupsOutputId, xupsOutputName, xupsOutputCurrentHighPrecision,
xupsOutputPercentLoad, xupsOutputVA in the table xupsOutputTable.
Add new sub collection xupsOutputTotal with xupsOutputAverageVoltage, xupsOutputAverageCurrent,
xupsOutputTotalWatts, xupsOutputTotalVA, xupsOutputAveragePowerFactor inside.
Add new data xupsBypassId, xupsBypassName, xupsBypassCurrentHighPrecision,
xupsBypassWatts in the table xupsBypassTable.
Add new sub collection xupsBypassTotal with xupsBypassTotalAverageVoltage, xupsBypassAverageCurrent,
xupsBypassTotalWatts, xupsBypassTotalVA, xupsBypassTotalAverageFactor inside."
REVISION "201804230000Z"
DESCRIPTION
"Add new data xupsTestTrap, xupstdTestTrap that will allow to initiate a
test trap sent out from the agent to the trap receivers."
REVISION "201211261513Z"
DESCRIPTION
"Add the identifier of measures xupsInputId, xupsOutputId and xupsBypassId,
respectively in the table xupsInputTable, xupsOutputTable and xupsBypassTable."
REVISION "201204030000Z"
DESCRIPTION
"Add new data xupsOutputHourlyPowerUsage, xupsOutputCumulativePowerUsage,
and xupsOutputCumulativePowerUsageTimer into the collection xupsOutput.
Add new data xupsRecepHourlyPowerUsage, xupsRecepCumulativePowerUsage,
and xupsRecepCumulativePowerUsageTimer into the collection xupsRecepTable."
REVISION "201102250000Z"
DESCRIPTION
"Add new data xupsSwitchable"
REVISION "200810020000Z"
DESCRIPTION
"Added new values of batteryDisconnected(6), batteryUnderTest(7),
and checkBattery(8) to xupsBatteryAbmStatus."
REVISION "200705030000Z"
DESCRIPTION
"Added new value of pxg(5) to xupsSendTrapType
for Power Xpert Gateway implementations."
REVISION "200703130000Z"
DESCRIPTION
"Initial SNMPv2-SMI-compliant Version of PowerMIB.
Incorporates all revisions of the original xups
MIB file through Version 3.13 21-May-04."
::= { eaton 1 }
-- xupsMIB { iso org(3) dod(6) internet(1) private(4)
-- enterprises(1) eaton(534) xupsMIB(1) }
xupsIdent OBJECT IDENTIFIER ::= { xupsMIB 1 }
xupsBattery OBJECT IDENTIFIER ::= { xupsMIB 2 }
xupsInput OBJECT IDENTIFIER ::= { xupsMIB 3 }
xupsOutput OBJECT IDENTIFIER ::= { xupsMIB 4 }
xupsBypass OBJECT IDENTIFIER ::= { xupsMIB 5 }
-- xupsEnvironment OBJECT IDENTIFIER ::= { xupsMIB 6 } - defined in EATON-OIDS
xupsAlarm OBJECT IDENTIFIER ::= { xupsMIB 7 }
xupsTest OBJECT IDENTIFIER ::= { xupsMIB 8 }
xupsControl OBJECT IDENTIFIER ::= { xupsMIB 9 }
xupsConfig OBJECT IDENTIFIER ::= { xupsMIB 10 }
xupsTrapControl OBJECT IDENTIFIER ::= { xupsMIB 11 }
xupsRecep OBJECT IDENTIFIER ::= { xupsMIB 12 }
xupsTopology OBJECT IDENTIFIER ::= { xupsMIB 13 }
xupsAgent OBJECT IDENTIFIER ::= { xupsMIB 14 }
xupsInputTotal OBJECT IDENTIFIER ::= { xupsInput 8 }
xupsOutputTotal OBJECT IDENTIFIER ::= { xupsOutput 9 }
xupsBypassTotal OBJECT IDENTIFIER ::= { xupsBypass 4 }
--
-- xupsIdent group:
--
xupsIdentManufacturer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UPS Manufacturer Name (e.g. Eaton Corporation)."
::= { xupsIdent 1}
xupsIdentModel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UPS Model (e.g. Powerware Plus Model 18)."
::= {xupsIdent 2}
xupsIdentSoftwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The firmware revision level(s) of the UPS microcontroller(s)."
::= {xupsIdent 3}
xupsIdentOemCode OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A binary code indicating who the UPS was manufactured or labeled for.
0 or 255 indicates Eaton itself."
::= {xupsIdent 4}
xupsIdentPartNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The catalog part number of the UPS device."
::= { xupsIdent 5 }
xupsIdentSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of the UPS device."
::= { xupsIdent 6 }
--
-- xupsBattery group:
--
xupsBatTimeRemaining OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Battery run time in seconds before UPS turns off due
to low battery."
::= { xupsBattery 1}
xupsBatVoltage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Volts DC"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Battery voltage as reported by the UPS meters."
::= {xupsBattery 2}
xupsBatCurrent OBJECT-TYPE
SYNTAX Integer32 (-2147483648..2147483647)
UNITS "Amps DC"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Battery Current as reported by the UPS metering.
Current is positive when discharging, negative
when recharging the battery."
::= {xupsBattery 3}
xupsBatCapacity OBJECT-TYPE
SYNTAX Integer32 (0..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Battery percent charge."
::= { xupsBattery 4}
xupsBatteryAbmStatus OBJECT-TYPE
SYNTAX INTEGER {
batteryCharging(1),
batteryDischarging(2),
batteryFloating(3),
batteryResting(4),
unknown(5),
batteryDisconnected(6),
batteryUnderTest(7),
checkBattery(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the status of the Advanced Battery Management and Battery state;
batteryFloating(3) status means that the charger is temporarily
charging the battery to its float voltage; batteryResting(4) is the
state when the battery is fully charged and none of the other actions
(charging/discharging/floating) is being done.
checkBattery(8) indicates that the Battery state is uncertain
following a poor battery test result."
::= { xupsBattery 5}
xupsBatteryLastReplacedDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date when the Batteries in this UPS were last replaced. Free text format,
so the preferred local date format may be used (MM/DD/YYYY, DD-Mon-YYYY, etc)."
::= { xupsBattery 6}
xupsBatteryFailure OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if a battery fault detected or battery tests failed."
::= { xupsBattery 7}
xupsBatteryNotPresent OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if the UPS has no battery either internal or external."
::= { xupsBattery 8}
xupsBatteryAged OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if the battery is over aged."
::= { xupsBattery 9}
xupsBatteryLowCapacity OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if the battery capacity is below the threshold set in the UPS."
::= { xupsBattery 10}
--
-- xupsInput group:
--
xupsInputFrequency OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "0.1 Hertz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The utility line frequency in tenths of Hz."
::= {xupsInput 1}
xupsInputLineBads OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the Input was out of tolerance
in voltage or frequency."
::= {xupsInput 2}
xupsInputNumPhases OBJECT-TYPE
SYNTAX Integer32 (0..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of input phases (normally 1 to 3)."
::= {xupsInput 3}
xupsInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF XupsInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of input table entries. The number of entries
is given by the value of xupsInputNumPhases."
::= {xupsInput 4}
xupsInputEntry OBJECT-TYPE
SYNTAX XupsInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The input table entry containing the current,
voltage, etc. readings for one phase."
INDEX { xupsInputPhase }
::= { xupsInputTable 1 }
XupsInputEntry ::= SEQUENCE {
xupsInputPhase Integer32,
xupsInputVoltage Integer32,
xupsInputCurrent Integer32,
xupsInputWatts Integer32,
xupsInputId INTEGER,
xupsInputName OCTET STRING,
xupsInputCurrentHighPrecision Integer32,
xupsInputVoltagePhaseToPhase Integer32
}
xupsInputPhase OBJECT-TYPE
SYNTAX Integer32 (0..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the phase. Serves as index for input table."
::= {xupsInputEntry 1}
xupsInputVoltage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured input voltage from the UPS meters in volts."
::= {xupsInputEntry 2}
xupsInputCurrent OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured input current from the UPS meters in amps."
::= {xupsInputEntry 3}
xupsInputWatts OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured input real power in watts."
::= {xupsInputEntry 4}
xupsInputId OBJECT-TYPE
SYNTAX INTEGER {
phase1toN (1),
phase2toN (2),
phase3toN (3),
phase1to2 (4),
phase2to3 (5),
phase3to1 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"value indicates what measurement is being stored in this table row :
phase1 to neutral, phase2 to neutral, phase3 to neutral,
phase1 to phase2, phase2 to phase3, phase3 to phase1."
::= { xupsInputEntry 5 }
xupsInputName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A descriptive name for the phase, example : L1/A for the phase 1."
::= { xupsInputEntry 6 }
xupsInputCurrentHighPrecision OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS tenth of Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured input current from the UPS meters in tenth of amps."
::= {xupsInputEntry 7}
xupsInputVoltagePhaseToPhase OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured input phase to phase voltage from the UPS meters in volts,
For the phase n, it is the measure of phase n to phase n+1 voltage."
::= {xupsInputEntry 8}
xupsInputSource OBJECT-TYPE
SYNTAX INTEGER {
other(1),
none(2),
primaryUtility(3),
bypassFeed(4),
secondaryUtility(5),
generator(6),
flywheel(7),
fuelcell(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The present external source of input power. The enumeration
'none(2)' indicates that there is no external source of
power, for example, the UPS is On Battery (an internal source).
'primaryUtility' indicates the normal case of utility input power.
The 'bypassFeed' can only be used when the Bypass source is known
to be a separate utility feed than the primaryUtility(3).
'secondaryUtility' indicates that a secondary utility feed is supplying
power (on a dual AC input UPS).
'generator' indicates that input power is provided by a generator.
Note that the alternate energy sources of 'flywheel' and 'fuelcell' are
not necessarily AC input sources."
::= { xupsInput 5 }
-- xupsDualInputStatus and xupsSecondaryInputWatch would only be present
-- for UPSs with a secondary input source.
xupsDualInputStatus OBJECT-TYPE
SYNTAX INTEGER {
bothSourcesBad(1),
primarySourceGood(2),
secondarySourceGood(3),
bothSourcesGood(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The present status of the sources of input power in a dual source UPS.
The enumeration primarySourceGood(2) indicates that the primary source
of power is present and within 'normal' ranges for voltage and
frequency, but the secondary source is either not present or not in an
acceptable range.
'secondarySourceGood' indicates that only the Secondary power feed is
available and within its limits.
The enumeration bothSourcesGood(4) indicates that both sources are present
and within their respective 'normal' ranges;
bothSourcesBad(1) indicates that neither source is present, or, if present,
is not within acceptable ranges.
This object will only be implemented for UPSs with two sources of input
power, e.g., redundant AC feeds or a separate Bypass or Generator source.
The secondary source will not be an AC power source in all cases."
::= { xupsInput 6 }
xupsSecondaryInputWatch OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables(2) or disables(1) the alarms and traps related to the
availability and use of the secondary input of a dual-input UPS
(i.e., OnAlternatePowerSource and AltPowerNotAvailable).
To avoid nuisance alarms and traps, this object should be set to
disabled(1) when the UPS is not wired to a secondary source of power.
This object will only be implemented for UPSs with two sources of input
power, i.e., redundant AC feeds or a separate Bypass or Generator source."
::= { xupsInput 7 }
--
-- xupsInputTotal group:
--
xupsInputAverageVoltage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured input voltage from the UPS meters in volts.
Related to the phase 1 if the UPS is single phase,
either it is average of all the simple phase voltage."
::= {xupsInputTotal 1}
xupsInputTotalCurrent OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS tenth of Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured input current from the UPS meters in tenth of amps.
Related to the phase 1 if the UPS is single phase,
either it is average of all the simple phase current."
::= {xupsInputTotal 2}
xupsInputTotalWatts OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured input active power in watts.
Sum of all the simple phase watts."
::= {xupsInputTotal 3}
xupsInputTotalVA OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "VA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured input apparent power in VA.
Sum of all the simple phase VA."
::= {xupsInputTotal 4}
xupsInputAveragePowerFactor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the total power factor of the input in hundredths.
0.92 would be returned as 92."
::= { xupsInputTotal 5 }
xupsInputStatus OBJECT-TYPE
SYNTAX INTEGER {
inputBad(1),
inputGood(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The present status of the primary AC input of the UPS.
The enumeration inputGood(2) indicates that the primary source
of power is present and within 'normal' ranges for voltage and
frequency.
inputBad(1) indicates that neither source is present, or, if present,
is not within acceptable ranges."
::= { xupsInput 9 }
--
-- xupsOutput group:
--
xupsOutputLoad OBJECT-TYPE
SYNTAX Integer32 (0..200)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UPS output load in percent of rated capacity."
::= {xupsOutput 1}
xupsOutputFrequency OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "0.1 Hertz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured UPS output frequency in tenths of Hz."
::= {xupsOutput 2}
xupsOutputNumPhases OBJECT-TYPE
SYNTAX Integer32 (0..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of metered output phases."
::= {xupsOutput 3}
xupsOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF XupsOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of output table entries. The number of entries
is given by the value of xupsOutputNumPhases."
::= {xupsOutput 4}
xupsOutputEntry OBJECT-TYPE
SYNTAX XupsOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Output Table Entry containing voltage, current, etc."
INDEX { xupsOutputPhase }
::= {xupsOutputTable 1}
XupsOutputEntry ::= SEQUENCE {
xupsOutputPhase Integer32,
xupsOutputVoltage Integer32,
xupsOutputCurrent Integer32,
xupsOutputWatts Integer32,
xupsOutputId INTEGER,
xupsOutputName OCTET STRING,
xupsOutputCurrentHighPrecision Integer32,
xupsOutputPercentLoad Integer32,
xupsOutputVA Integer32,
xupsOutputVoltagePhaseToPhase Integer32
}
xupsOutputPhase OBJECT-TYPE
SYNTAX Integer32 (0..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the phase. Serves as index for output table."
::= {xupsOutputEntry 1}
xupsOutputVoltage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured output voltage from the UPS metering in volts."
::= {xupsOutputEntry 2}
xupsOutputCurrent OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured UPS output current in amps."
::= {xupsOutputEntry 3}
xupsOutputWatts OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured real output power in watts."
::= {xupsOutputEntry 4}
xupsOutputId OBJECT-TYPE
SYNTAX INTEGER {
phase1toN (1),
phase2toN (2),
phase3toN (3),
phase1to2 (4),
phase2to3 (5),
phase3to1 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"value indicates what measurement is being stored in this table row :
phase1 to neutral, phase2 to neutral, phase3 to neutral,
phase1 to phase2, phase2 to phase3, phase3 to phase1. "
::= { xupsOutputEntry 5 }
xupsOutputName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A descriptive name for the phase."
::= { xupsOutputEntry 6 }
xupsOutputCurrentHighPrecision OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS tenth of Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured output current from the UPS meters in tenth of amps."
::= {xupsOutputEntry 7}
xupsOutputPercentLoad OBJECT-TYPE
SYNTAX Integer32 (0..200)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of the UPS power capacity presently
being used on this output line"
::= { xupsOutputEntry 8 }
xupsOutputVA OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "VA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured apparent output power in VA."
::= {xupsOutputEntry 9}
xupsOutputVoltagePhaseToPhase OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured output phase to phase voltage from the UPS meters in volts,
For the phase n, it is the measure of phase n to phase n+1 voltage."
::= {xupsOutputEntry 10}
xupsOutputSource OBJECT-TYPE
SYNTAX INTEGER {
other(1),
none(2),
normal(3),
bypass(4),
battery(5),
booster(6),
reducer(7),
parallelCapacity(8),
parallelRedundant(9),
highEfficiencyMode(10),
maintenanceBypass(11),
essMode(12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The present source of output power. The enumeration
none(2) indicates that there is no source of output
power (and therefore no output power), for example,
the system has opened the output breaker.
'normal', 'bypass', and 'battery' indicate those common UPS statuses.
'booster' and 'reducer' indicate boost or buck operation, for
line-interactive UPSs only.
'parallelCapacity' and 'parallelRedundant' indicate a normal parallel
UPS system, in either Parallel for Capacity or Redundancy configuration.
'highEfficiencyMode' is normal but enhanced by High Efficiency mode.
'maintenanceBypass' indicates that the UPS is in Maintenance/Manual
Bypass mode.
'essMode' is normal but enhanced by Energy Saver System.
'other' covers any other, unusual conditions."
::= { xupsOutput 5 }
xupsOutputHourlyPowerUsage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Wh"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Units are Watt-hours.This is the energy consumed during the last hour."
::= { xupsOutput 6 }
xupsOutputCumulativePowerUsage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Wh"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Units are Watt-hours.This is the energy consumed since the last reset.
This object is writable so that it can be reset to 0.
When it is written to 0, the xupsOutputCumulativeWhTimer will be reset to 0 as well."
::= { xupsOutput 7 }
xupsOutputCumulativePowerUsageTimer OBJECT-TYPE
SYNTAX Counter32
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time in seconds since the cumulative power usage was last reset."
::= { xupsOutput 8 }
--
-- xupsOutputTotal group:
--
xupsOutputAverageVoltage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured output voltage from the UPS meters in volts.
Related to the phase 1 if the UPS is single phase,
either it is average of all the simple phase voltage."
::= {xupsOutputTotal 1}
xupsOutputTotalCurrent OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS tenth of Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured output current from the UPS meters in tenth of amps.
Related to the phase 1 if the UPS is single phase,
either it is average of all the simple phase current."
::= {xupsOutputTotal 2}
xupsOutputTotalWatts OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured output active power in watts.
Sum of all the simple phase watts."
::= {xupsOutputTotal 3}
xupsOutputTotalVA OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "VA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured output apparent power in VA.
Sum of all the simple phase VA."
::= {xupsOutputTotal 4}
xupsOutputAveragePowerFactor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the total power factor of the output in hundredths.
0.92 would be returned as 92."
::= { xupsOutputTotal 5 }
xupsOutputStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
outputNotPowered(1),
outputNotProtected(2),
outputProtected(3),
outputPoweredNoContinuity(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The present status of the AC output of the UPS.
The enumeration outputNotPowered(1) indicates that the output is not powered.
outputNotProtected(2) indicates that the output is powered but not protected,
due to following reasons : On bypass, battery fault, or UPS internal failure
that makes the ups will be inoperant in case of AC input failure.
outputProtected(3) indicates that the output is powered and protected.
outputPoweredNoContinuity(4) indicates that the output is powered but this
is a specific configuration of the device where the continuity feature is disabled."
::= { xupsOutput 10 }
--
-- xupsBypass group:
--
xupsBypassFrequency OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "0.1 Hertz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The bypass frequency in tenths of Hz."
::= {xupsBypass 1}
xupsBypassNumPhases OBJECT-TYPE
SYNTAX Integer32 (0..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of lines in the UPS bypass table."
::= {xupsBypass 2}
xupsBypassTable OBJECT-TYPE
SYNTAX SEQUENCE OF XupsBypassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of bypass table entries. The number of entries
is given by the value of xupsBypassNumPhases."
::= {xupsBypass 3}
xupsBypassEntry OBJECT-TYPE
SYNTAX XupsBypassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Bypass Table Entry containing voltage for each phase."
INDEX { xupsBypassPhase }
::= {xupsBypassTable 1}
XupsBypassEntry ::= SEQUENCE {
xupsBypassPhase Integer32,
xupsBypassVoltage Integer32,
xupsBypassId INTEGER,
xupsBypassName OCTET STRING,
xupsBypassCurrentHighPrecision Integer32,
xupsBypassWatts Integer32,
xupsBypassVoltagePhaseToPhase Integer32
}
xupsBypassPhase OBJECT-TYPE
SYNTAX Integer32 (0..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Bypass Phase, index for the table."
::= {xupsBypassEntry 1}
xupsBypassVoltage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured UPS bypass voltage in volts."
::= {xupsBypassEntry 2}
xupsBypassId OBJECT-TYPE
SYNTAX INTEGER {
phase1toN (1),
phase2toN (2),
phase3toN (3),
phase1to2 (4),
phase2to3 (5),
phase3to1 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"value indicates what measurement is being stored in this table row :
phase1 to neutral, phase2 to neutral, phase3 to neutral,
phase1 to phase2, phase2 to phase3, phase3 to phase1. "
::= { xupsBypassEntry 3 }
xupsBypassName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A descriptive name for the phase."
::= { xupsBypassEntry 4 }
xupsBypassCurrentHighPrecision OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS tenth of Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured bypass current from the UPS meters in tenth of amps."
::= {xupsBypassEntry 5}
xupsBypassWatts OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured real bypass power in watts."
::= {xupsBypassEntry 6}
xupsBypassVoltagePhaseToPhase OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured bypass phase to phase voltage from the UPS meters in volts,
For the phase n, it is the measure of phase n to phase n+1 voltage."
::= {xupsBypassEntry 7}
-- xupsBypassTotal group:
xupsBypassAverageVoltage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured bypass voltage from the UPS meters in volts.
Related to the phase 1 if the UPS is single phase,
either it is average of all the simple phase voltage."
::= {xupsBypassTotal 1}
xupsBypassTotalCurrent OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS tenth of Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured bypass current from the UPS meters in tenth of amps.
Related to the phase 1 if the UPS is single phase,
either it is average of all the simple phase current."
::= {xupsBypassTotal 2}
xupsBypassTotalWatts OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured bypass active power in watts.
Sum of all the simple phase watts."
::= {xupsBypassTotal 3}
xupsBypassTotalVA OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "VA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured output apparent power in VA.
Sum of all the simple phase VA."
::= {xupsBypassTotal 4}
xupsBypassAveragePowerFactor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the total power factor of the input in hundredths.
0.92 would be returned as 92."
::= { xupsBypassTotal 5 }
--
-- xupsEnvironment group:
--
xupsEnvAmbientTemp OBJECT-TYPE
SYNTAX Integer32 (-100..200)
UNITS "degrees Centigrade"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reading of the ambient temperature in the vicinity of the
UPS or SNMP agent."
::= { xupsEnvironment 1 }
xupsEnvAmbientLowerLimit OBJECT-TYPE
SYNTAX Integer32 (-100..200)
UNITS "degrees Centigrade"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Lower Limit of the ambient temperature; if xupsEnvAmbientTemp
falls below this value, the xupsAmbientTempBad alarm will occur."
::= { xupsEnvironment 2 }
xupsEnvAmbientUpperLimit OBJECT-TYPE
SYNTAX Integer32 (-100..200)
UNITS "degrees Centigrade"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Upper Limit of the ambient temperature; if xupsEnvAmbientTemp
rises above this value, the xupsAmbientTempBad alarm will occur.
This value should be greater than xupsEnvAmbientLowerLimit."
::= { xupsEnvironment 3 }
xupsEnvAmbientHumidity OBJECT-TYPE
SYNTAX Integer32 (0..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reading of the ambient humidity in the vicinity of the
UPS or SNMP agent."
::= { xupsEnvironment 4 }
--
-- Moved the EMP-based objects,
-- from xupsEnvRemoteTemp to xupsEnvRemoteCommunicationStatus
-- ( { xupsEnvironment 5 to 13 }, including xupsContactSenseTable,
-- to separate file Eaton-EMP-MIB.txt
--
--
-- xupsAlarm group:
--
xupsAlarms OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of alarm conditions."
::= {xupsAlarm 1}
xupsAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF XupsAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of alarm table entries. The number of entries
is given by the value of xupsAlarms.
Note that this table is sparsely (non-consecutively)
numbered and will be empty if there are no active alarms."
::= {xupsAlarm 2}
xupsAlarmEntry OBJECT-TYPE
SYNTAX XupsAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Alarm Table Entry containing descriptive information
for one alarm entry."
INDEX { xupsAlarmID }
::= {xupsAlarmTable 1}
XupsAlarmEntry ::= SEQUENCE {
xupsAlarmID Integer32,
xupsAlarmDescr OBJECT IDENTIFIER,
xupsAlarmTime TimeTicks
}
xupsAlarmID OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier for an alarm condition."
::= {xupsAlarmEntry 1}
xupsAlarmDescr OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to an alarm description object. The object
referenced should not be accessible, but rather be used to
provide a unique description of the alarm condition."
::= {xupsAlarmEntry 2}
xupsAlarmTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the MIB-II variable sysUpTime when the alarm
condition occurred."
::= {xupsAlarmEntry 3}
--
-- Well known alarm conditions.
--
xupsOnBattery OBJECT IDENTIFIER ::= {xupsAlarm 3}
xupsLowBattery OBJECT IDENTIFIER ::= {xupsAlarm 4}
xupsUtilityPowerRestored OBJECT IDENTIFIER ::= {xupsAlarm 5}
xupsReturnFromLowBattery OBJECT IDENTIFIER ::= {xupsAlarm 6}
xupsOutputOverload OBJECT IDENTIFIER ::= {xupsAlarm 7}
xupsInternalFailure OBJECT IDENTIFIER ::= {xupsAlarm 8}
xupsBatteryDischarged OBJECT IDENTIFIER ::= {xupsAlarm 9}
xupsInverterFailure OBJECT IDENTIFIER ::= {xupsAlarm 10}
xupsOnBypass OBJECT IDENTIFIER ::= {xupsAlarm 11}
xupsBypassNotAvailable OBJECT IDENTIFIER ::= {xupsAlarm 12}
xupsOutputOff OBJECT IDENTIFIER ::= {xupsAlarm 13}
xupsInputFailure OBJECT IDENTIFIER ::= {xupsAlarm 14}
xupsBuildingAlarm OBJECT IDENTIFIER ::= {xupsAlarm 15}
xupsShutdownImminent OBJECT IDENTIFIER ::= {xupsAlarm 16}
xupsOnInverter OBJECT IDENTIFIER ::= {xupsAlarm 17}
xupsAlarmNumEvents OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of entries in the UPS event history queue."
::= { xupsAlarm 18 }
xupsAlarmEventTable OBJECT-TYPE
SYNTAX SEQUENCE OF XupsAlarmEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the UPS internal event history queue."
::= { xupsAlarm 19 }
xupsAlarmEventEntry OBJECT-TYPE
SYNTAX XupsAlarmEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"One of the entries in the UPS event history queue."
INDEX { xupsAlarmEventID }
::= { xupsAlarmEventTable 1 }
-- The first 4 vars in the xAEEntry have been deprecated, since they resulted in
-- a flood of difficult to interpret data. They have been replaced by the single
-- entry, xupsAlarmEventMsg, which gives a human-readable description of the event.
XupsAlarmEventEntry ::= SEQUENCE {
xupsAlarmEventID Integer32,
xupsAlarmEventDateAndTime DisplayString,
xupsAlarmEventKind INTEGER,
xupsAlarmEventDescr Integer32,
xupsAlarmEventMsg DisplayString
}
xupsAlarmEventID OBJECT-TYPE
SYNTAX Integer32 (1..400)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique number that reflects the order in which the event
occurred. The oldest event in the queue will be number 1.
Subsequent events will be numbered 2, 3, 4, etc."
::= { xupsAlarmEventEntry 1 }
xupsAlarmEventDateAndTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..22))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The time and date that an event occurred as recorded in the UPS
internal event queue. This string will reflect the time and
date as set in the UPS itself and will not be referenced to sysUpTime.
The format is MM/DD/YYYY:HH:MM:SS. Time is 24 hour standard."
::= { xupsAlarmEventEntry 2 }
xupsAlarmEventKind OBJECT-TYPE
SYNTAX INTEGER {
occurred (1),
cleared (2),
unknown (3)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Enumerated value that tells whether the event is an
occurrence of an alarm condition or a clearing of an
alarm condition."
::= { xupsAlarmEventEntry 3 }
xupsAlarmEventDescr OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"A description of the event stored in the UPS event queue.
This description will be a sixteen bit integer value
representing one of the defined alarms in the Powerware Binary
Computer Mode communication specification; for example,
a value of 0 represents the 'Inverter AC Over Voltage'
alarm (byte 1, bit 0 in the BCM Alarm Map)."
::= { xupsAlarmEventEntry 4 }
xupsAlarmEventMsg OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A text string describing each entry in the Event Log. The format of this
text message is free (not fixed) for the operator to read; good contents
would be a time & date stamp, the event type, and a description of the event."
::= { xupsAlarmEventEntry 5 }
--
-- More Well known alarm conditions.
--
xupsBreakerOpen OBJECT IDENTIFIER ::= {xupsAlarm 20}
xupsAlarmEntryAdded OBJECT IDENTIFIER ::= {xupsAlarm 21}
xupsAlarmEntryRemoved OBJECT IDENTIFIER ::= {xupsAlarm 22}
-- Same as RFC 1628 Well Known Alarms:
xupsAlarmBatteryBad OBJECT IDENTIFIER ::= {xupsAlarm 23}
xupsOutputOffAsRequested OBJECT IDENTIFIER ::= {xupsAlarm 24}
xupsDiagnosticTestFailed OBJECT IDENTIFIER ::= {xupsAlarm 25}
xupsCommunicationsLost OBJECT IDENTIFIER ::= {xupsAlarm 26}
xupsUpsShutdownPending OBJECT IDENTIFIER ::= {xupsAlarm 27}
xupsAlarmTestInProgress OBJECT IDENTIFIER ::= {xupsAlarm 28}
-- Alarm for the Ambient Temperature, when outside of lo/hi limits
xupsAmbientTempBad OBJECT IDENTIFIER ::= {xupsAlarm 29}
-- For Loss of Redundancy in parallel systems
xupsLossOfRedundancy OBJECT IDENTIFIER ::= {xupsAlarm 30}
-- More Same as RFC 1628 Well Known Alarms:
xupsAlarmTempBad OBJECT IDENTIFIER ::= {xupsAlarm 31}
xupsAlarmChargerFailed OBJECT IDENTIFIER ::= {xupsAlarm 32}
xupsAlarmFanFailure OBJECT IDENTIFIER ::= {xupsAlarm 33}
xupsAlarmFuseFailure OBJECT IDENTIFIER ::= {xupsAlarm 34}
-- A Relay, Contactor, or Breaker has failed
xupsPowerSwitchBad OBJECT IDENTIFIER ::= {xupsAlarm 35}
-- One module in a parallel or composite system has failed
xupsModuleFailure OBJECT IDENTIFIER ::= {xupsAlarm 36}
-- Two Alarms for systems with an Alternate Power Source, such as
-- Secondary utility feed (on a dual AC input UPS), generator,
-- flywheel, or fuelcell. Enabled by xupsSecondaryInputWatch.
xupsOnAlternatePowerSource OBJECT IDENTIFIER ::= {xupsAlarm 37}
xupsAltPowerNotAvailable OBJECT IDENTIFIER ::= {xupsAlarm 38}
-- Some Notice condition exists which is not covered by the other WKA
-- (like an xupsInternalFailure, but at a lower level of urgency)
xupsNoticeCondition OBJECT IDENTIFIER ::= {xupsAlarm 39}
-- Alarms for the Remote Temperature & Humidity, when outside of lo/hi limits
xupsRemoteTempBad OBJECT IDENTIFIER ::= {xupsAlarm 40}
xupsRemoteHumidityBad OBJECT IDENTIFIER ::= {xupsAlarm 41}
-- Last of the RFC1628 Well Known Alarms:
xupsAlarmOutputBad OBJECT IDENTIFIER ::= {xupsAlarm 42}
xupsAlarmAwaitingPower OBJECT IDENTIFIER ::= {xupsAlarm 43}
-- Alarm for this important UPS mode
xupsOnMaintenanceBypass OBJECT IDENTIFIER ::= {xupsAlarm 44}
-- New alarms now managed by the Network-M2 card
xupsOutputNotProtected OBJECT IDENTIFIER ::= {xupsAlarm 51}
--
-- xupsTest group:
--
xupsTestStart OBJECT-TYPE
SYNTAX INTEGER {
testBattery (1),
noTestStarted (2),
testSystem (3),
testSecondarySource (4),
flashLightsTest (5),
cancelTest (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object initiates the requested Test.
The test types which a UPS might support are 'testBattery',
'testSystem' (a UPS General Systems test, however defined by the UPS),
'testSecondarySource' (test if the Secondary power source is good on a
dual input UPS), and
'flashLightsTest' (start a test which flashes the UPS lights, and if
available, sounds the horn to help locate the UPS).
If a UPS does not support the requested test, the set operation may
succeed but the xupsTestBatteryStatus will end up as notSupported.
When read, this object indicates the last test requested via this object,
if any; 'noTestStarted' could be the initial value.
Currently only the 'flashLightsTest' can be canceled with 'cancelTest'."
::= {xupsTest 1}
xupsTestBatteryStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
passed (2),
failed (3),
inProgress (4),
notSupported (5),
inhibited (6),
scheduled (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reading this enumerated value gives an indication of the (last)
UPS Battery test status.
'inhibited' means that the battery test could not be run.
'scheduled' means that the battery test could not be run at the time
of request, but will be run at some later (UPS-determined) time."
::= {xupsTest 2}
xupsLastGeneralTest OBJECT-TYPE
SYNTAX INTEGER {
noTestStarted (2),
testSystem (3),
testSecondarySource (4),
flashLightsTest (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the last UPS test requested via xupsTestStart or by other
non-SNMP means, other than for the testBattery (1) case.
The results of the test indicated by this object are reported in
xupsLastGeneralTestResult."
::= {xupsTest 3}
xupsLastGeneralTestResult OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
passed (2),
failed (3),
inProgress (4),
notSupported (5),
inhibited (6),
scheduled (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reading this enumerated value gives the result of the test indicated
in xupsLastGeneralTest."
::= {xupsTest 4}
xupsTestTrap OBJECT-TYPE
SYNTAX INTEGER { startTestTrap (1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting startTestTrap to 1 will initiate a test trap
to be sent out from the agent. All other set values are invalid."
::= {xupsTest 5}
--
-- xupsControl group:
--
xupsControlOutputOffDelay OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this value to other than zero will cause the UPS
output to turn off after the number of seconds.
Setting it to 0 will cause an attempt to abort a pending
shutdown."
::= {xupsControl 1}
xupsControlOutputOnDelay OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this value to other than zero will cause the UPS
output to turn on after the number of seconds.
Setting it to 0 will cause an attempt to abort a pending
startup."
::= {xupsControl 2}
xupsControlOutputOffTrapDelay OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When xupsControlOutputOffDelay reaches this value, a trap will
be sent."
::= {xupsControl 3}
xupsControlOutputOnTrapDelay OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "seconds"
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"When xupsControlOutputOnDelay reaches this value, a
xupsOutputOff trap will be sent."
::= {xupsControl 4}
xupsControlToBypassDelay OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this value to other than zero will cause the UPS
output to go to Bypass after the number of seconds.
If the Bypass is unavailable, this may cause the UPS
to not supply power to the load.
Setting it to 0 will cause an attempt to abort a pending
shutdown."
::= {xupsControl 5}
xupsLoadShedSecsWithRestart OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this value will cause the UPS output to turn off
after the set number of seconds, then restart (after a UPS-defined
'down time') when the utility is again available.
Unlike xupsControlOutputOffDelay, which might or might not,
this object always maps to the XCP 0x8A Load Dump & Restart command,
so the desired shutdown and restart behavior is guaranteed to happen.
Once set, this command cannot be aborted.
This is the preferred Control object to use when performing
an On Battery OS Shutdown."
::= {xupsControl 6}
xupsSwitchable OBJECT-TYPE
SYNTAX INTEGER {
switchable (1),
notSwitchable (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Parameter which indicates whether UPS commands received via any
communication path (aside from manual controls) are able (switchable)
or not able (notSwitchable) to control the UPS."
::= { xupsControl 7 }
--
-- xupsConfig group:
--
xupsConfigOutputVoltage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal UPS Output voltage per phase in volts."
::= {xupsConfig 1}
xupsConfigInputVoltage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal UPS Input voltage per phase in volts."
::= {xupsConfig 2}
xupsConfigOutputWatts OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal UPS available real power output in watts."
::= {xupsConfig 3}
xupsConfigOutputFreq OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "0.1 Hertz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal output frequency in tenths of Hz."
::= {xupsConfig 4}
xupsConfigDateAndTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..22))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Date and time information for the UPS. Setting this variable
will initiate a set UPS date and time to this value. Reading
this variable will return the UPS time and date. This value
is not referenced to sysUpTime. It is simply the clock value
from the UPS real time clock.
Format is as follows: MM/DD/YYYY:HH:MM:SS."
::= { xupsConfig 5 }
xupsConfigLowOutputVoltageLimit OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Lower limit for acceptable Output Voltage, per the UPS
specifications."
::= {xupsConfig 6}
xupsConfigHighOutputVoltageLimit OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Upper limit for acceptable Output Voltage, per the UPS
specifications."
::= {xupsConfig 7}
xupsConfigInstallDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The date when this UPS was installed. Free text format, so the
preferred local date format may be used (MM/DD/YYYY, DD-Mon-YYYY, etc)."
::= {xupsConfig 8}
--
-- xupsTrapControl group:
--
xupsMaxTrapLevel OBJECT-TYPE
SYNTAX INTEGER {
none (1),
critical (2),
major (3),
minor (4),
allTraps (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The level of severity of traps which will be sent to the
requesting host; individual trap receivers will have
individual values for this variable. Values are:
(1) none: no traps will be sent to this host;
(2) critical: only traps for Critical alarm conditions will
be sent to this host;
(3) major: Critical and Major traps will be sent;
(4) minor: All levels of alarming traps will be sent: Critical,
Major, and Minor
(This level was added in PowerMIB v3.11)
(5) allTraps: all Traps will be sent to this host
(Critical, Major, Minor, Informational)."
::= {xupsTrapControl 1}
xupsSendTrapType OBJECT-TYPE
SYNTAX INTEGER {
stnd (1),
xups (2),
stndPlus (3),
xupsPlus (4),
pxg (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of traps which will be sent to the
requesting host; individual trap receivers will have
individual values for this variable. The additional
variables in types (3) and (4) are useful for determining
which UPS is the source on multi-port network adapters,
and for getting additional descriptive information.
Types (1) through (4) are all SNMP version 1 trap PDUs.
Values are:
(1) stnd: Traps as defined in the Standard UPS MIB (RFC1628)
and Generic (MIB II) traps as defined in RFC 1215.
(2) xups: xupsTrapDefined Traps as defined in the PowerMIB
and Generic (MIB II) traps as defined in RFC 1215.
(3 Deprecated) stndPlus: same as stnd plus variables from the interface
group and, where appropriate, xupsTrapMessage.
(4 Deprecated) xupsPlus: xupsTrapPortN Traps (same as xups plus
variables from the interface group) and,
for authFail, xupsTrapMessage.
(5 pxg: Traps as defined in the Power Xpert Gateway MIB
(PXG-MIB)."
::= {xupsTrapControl 2}
xupsTrapMessage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..79))
MAX-ACCESS read-only -- actually not-accessible
STATUS current
DESCRIPTION
"A descriptive text message which may be sent with traps to
further explain the reason for the trap.
This object is not-accessible to MIB browsers, but had to be changed to
read-only to satisfy SMIv2 syntax checkers since it is included in traps."
::= {xupsTrapControl 3}
-- An Identifier for the PowerMIB traps
-- Used below in the section where the traps are defined
xupsTrapSource OBJECT IDENTIFIER ::= {xupsTrapControl 4}
xupsHeartbeatMinsInterval OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How often to send the xupstdHeartbeat trap, in units of minutes.
A setting of 0 disables the Heartbeat function."
::= {xupsTrapControl 5}
--
-- xupsRecep group:
--
-- (Note that the terms Receptacle, Outlet, and Load Group are used interchangeably
-- here and all mean "one of a group of controllable, power-switched outputs")
--
xupsNumReceptacles OBJECT-TYPE
SYNTAX Integer32 (0..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of independently controllable Receptacles, as described in the
xupsRecepTable."
::= {xupsRecep 1}
xupsRecepTable OBJECT-TYPE
SYNTAX SEQUENCE OF XupsRecepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of receptacle table entries. The number of entries
is given by the value of xupsNumReceptacles."
::={xupsRecep 2}
xupsRecepEntry OBJECT-TYPE
SYNTAX XupsRecepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A receptacle table entry containing the status and
control values for one receptacle."
INDEX { xupsRecepIndex }
::= { xupsRecepTable 1 }
XupsRecepEntry ::= SEQUENCE {
xupsRecepIndex Integer32,
xupsRecepStatus INTEGER,
xupsRecepOffDelaySecs Integer32,
xupsRecepOnDelaySecs Integer32,
xupsRecepAutoOffDelay Integer32,
xupsRecepAutoOnDelay Integer32,
xupsRecepShedSecsWithRestart Integer32,
xupsRecepHourlyPowerUsage Integer32,
xupsRecepCumulativePowerUsage Integer32,
xupsRecepCumulativePowerUsageTimer Counter32
}
xupsRecepIndex OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the Receptacle. Serves as index for Receptacle table."
::= {xupsRecepEntry 1}
xupsRecepStatus OBJECT-TYPE
SYNTAX INTEGER {
on(1), off(2), pendingOff(3), pendingOn(4), unknown(5),
reserved(6), failedClosed(7), failedOpen(8) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Recep Status 1=On/Close, 2=Off/Open, 3=On w/Pending Off,
4=Off w/Pending ON, 5=Unknown, 6=Reserved for future,
7=Failed in Closed position, 8=Failed in Open position."
::={xupsRecepEntry 2}
xupsRecepOffDelaySecs OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Delay until the Receptacle is turned Off. Setting
this value to other than -1 will cause the UPS output to
turn off after the number of seconds (0 is immediately).
Setting it to -1 will cause an attempt to abort a pending shutdown.
When this object is set while the UPS is On Battery, it is not necessary
to set xupsRecepOnDelaySecs, since the outlet will turn back on
automatically when power is available again."
::= {xupsRecepEntry 3}
xupsRecepOnDelaySecs OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Delay until the Receptacle is turned On. Setting
this value to other than -1 will cause the UPS output to
turn on after the number of seconds (0 is immediately).
Setting it to -1 will cause an attempt to abort a pending restart."
::={xupsRecepEntry 4}
xupsRecepAutoOffDelay OBJECT-TYPE
SYNTAX Integer32 (-1..32767)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay after going On Battery until the Receptacle is
automatically turned Off. A value of -1 means that this Output should
never be turned Off automatically, but must be turned Off only by command.
Values from 0 to 30 are valid, but probably innappropriate.
The AutoOffDelay can be used to prioritize loads in the event of a prolonged
power outage; less critical loads will turn off earlier to extend battery
time for the more critical loads. If the utility power is restored before the
AutoOff delay counts down to 0 on an outlet, that outlet will not turn Off."
::= {xupsRecepEntry 5}
xupsRecepAutoOnDelay OBJECT-TYPE
SYNTAX Integer32 (-1..32767)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Seconds delay after the Outlet is signaled to turn On before the Output is
Automatically turned ON. A value of -1 means that this Output should never
be turned On automatically, but only when specifically commanded to do so.
A value of 0 means that the Receptacle should come On immediately
at power-up or for an On command."
::= {xupsRecepEntry 6}
-- xupsRecepAutoOnDelay has three purposes:
-- 1. To coordinate the automatic startup of various outlets, when the normal
-- auto-sequencing of 1 second per outlet is not adequate. For example, they may
-- be used to power up hard disk arrays before CPU units are started.
-- 2. To force additional 'Down Time' during xupsRecepOffDelaySecs commands, for
-- equipment to be reset, when the standard 'Down Time' is not long enough.
-- 3. For the -1 value, to ensure that loads won't be powered until commanded,
-- following power-up or a xupsRecepOffDelaySecs command.
xupsRecepShedSecsWithRestart OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this value will cause the UPS output to turn off
after the set number of seconds, then restart (after a UPS-defined
'down time') when the utility is again available.
Unlike xupsRecepOffDelaySecs, which might or might not,
this object always maps to the XCP 0x8A Load Dump & Restart command,
so the desired shutdown and restart behavior is guaranteed to happen.
Once set, this command cannot be aborted."
::= {xupsRecepEntry 7}
xupsRecepHourlyPowerUsage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Wh"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Units are Watt-hours.This is the energy consumed during the last hour."
::= { xupsRecepEntry 8 }
xupsRecepCumulativePowerUsage OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "Wh"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Units are Watt-hours.This is the energy consumed since the last reset.
This object is writable so that it can be reset to 0.
When it is written to 0, the xupsRecepCumulativePowerUsageTimer will be reset to 0 as well."
::= { xupsRecepEntry 9 }
xupsRecepCumulativePowerUsageTimer OBJECT-TYPE
SYNTAX Counter32
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time in seconds since the cumulative power usage was last reset."
::= { xupsRecepEntry 10 }
--
-- xupsTopology group:
--
xupsTopologyType OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value which denotes the type of UPS by its power topology. Values are the
same as those described in the XCP Topology block's Overall Topology field."
::= {xupsTopology 1}
xupsTopoMachineCode OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID Value which denotes the Powerware model of the UPS for software.
Values are the same as those described in the XCP Configuration
block's Machine Code field."
::= {xupsTopology 2}
xupsTopoUnitNumber OBJECT-TYPE
SYNTAX Integer32 (0..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies which unit and what type of data is being reported.
A value of 0 means that this MIB information comes from the top-level system
view (eg, manifold module or system bypass cabinet reporting total system
output). Standalone units also use a value of 0, since they are the 'full
system' view.
A value of 1 or higher indicates the number of the module in the system
which is reporting only its own data in the PowerMIB objects."
::= {xupsTopology 3}
xupsTopoPowerStrategy OBJECT-TYPE
SYNTAX INTEGER {
highAlert(1), standard(2), enableHighEfficiency(3),
immediateHighEfficiency(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Value which denotes which Power Strategy is currently set for the UPS.
The values are:
highAlert(1) - The UPS shall optimize its operating state to maximize its
power-protection levels. This mode will be held for at most 24 hours.
standard(2) - Balanced, normal power protection strategy. UPS will not enter
HE operating mode from this setting.
enableHighEfficiency(3) - The UPS is enabled to enter HE operating mode to
optimize its operating state to maximize its efficiency, when
conditions change to permit it (as determined by the UPS).
forceHighEfficiency(4) - If this value is permitted to be Set for this UPS,
and if conditions permit, requires the UPS to enter High Efficiency
mode now, without delay (for as long as utility conditions permit).
After successfully set to forceHighEfficiency(4),
xupsTopoPowerStrategy changes to value enableHighEfficiency(3).
xupsOutputSource will indicate if the UPS status is actually operating in
High Efficiency mode."
::= {xupsTopology 4}
--
-- xupsAgent group:
--
xupsAgentManufacturer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The card agent Manufacturer Name (e.g. Eaton Corporation)."
::= { xupsAgent 1}
xupsAgentModel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The card agent model"
::= {xupsAgent 2}
xupsAgentSoftwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The agent firmware version."
::= {xupsAgent 3}
xupsAgentPartNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The card agent catalog part number."
::= { xupsAgent 4 }
xupsAgentSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The card agent catalog serial number."
::= { xupsAgent 5 }
-- *************************************************************************
-- *************************************************************************
--
-- Traps (xupst)
--
-- 1) Eaton's traps have been defined in this MIB for three different sources.
-- The trap definitions for the three sources are very similar,
-- and use the same alarms as their triggers; their names are prefaced
-- by xupstb, xupstd, and xupstp to distinguish the three types
-- However, the products that the "Basic" and "Port Defined" trap types were
-- created for have been obsoleted, so the only trap types in active use
-- are the "Defined" (xupstd) traps listed below
-- The Obsolete types have been moved to file XUPS_Obsolete.mib
--
-- a) OBSOLETE - Basic Agents for which the trap variables have not been
-- defined, though trap variables are included with the trap PDU
-- xupsNull OBJECT IDENTIFIER ::= { xupsMIB 0 }
-- xupsTrapBasic OBJECT IDENTIFIER ::= { xupsNull 0 }
--
-- b) Agents with exactly Defined trap variables, which may be
-- used as input to trap response macros on management stations
-- This trap type is selected by setting xupsSendTrapType to xups(2)
xupsTrapDefined OBJECT IDENTIFIER ::= {xupsTrapSource 1}
-- Following the recommendations for coexistence between v1 traps
-- and v2 notifications, define the snmpTrapOID base with a 0
xupsTrapOidDefined OBJECT IDENTIFIER ::= { xupsTrapDefined 0 }
--
-- c) OBSOLETE - Agents with Defined traps including ifIndex and ifDescr,
-- which can be used to determine which UPS of a multi-port
-- agent (eg, Eaton Network SNMP Adapter) sent the trap
-- This trap type was selected by setting xupsSendTrapType to xupsPlus(4)
-- xupsTrapPortN OBJECT IDENTIFIER ::= {xupsTrapSource 2}
--
-- 2) Trap Severity Level is given as a comment to indicate which
-- xupsMaxTrapLevel will result in this trap being sent;
-- levels are (in order): Critical, Major, Minor, Informational
--
-- ****************************************************************************
-- ****************************************************************************
--
-- Traps from xupsTrapDefined source (xupstd):
--
xupstdControlOff NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The UPS output power will turn off in a number of
seconds equal to upsControlOutputOffTrapDelay."
--#SEVERITY CRITICAL
::= { xupsTrapOidDefined 1 }
xupstdControlOn NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The UPS output power will turn on in a number of
seconds equal to upsControlOutputOnTrapDelay."
--#SEVERITY INFORMATIONAL
::= { xupsTrapOidDefined 2 }
xupstdOnBattery NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The UPS has no AC input power and is running on
battery."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 3 }
xupstdLowBattery NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The UPS batteries are low. Tied to low battery
alarm condition."
--#SEVERITY CRITICAL
::= { xupsTrapOidDefined 4 }
xupstdUtilityPowerRestored NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"Input power has been restored after running on battery."
--#SEVERITY INFORMATIONAL
::= { xupsTrapOidDefined 5 }
xupstdReturnFromLowBattery NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The battery has recovered from a low battery condition."
--#SEVERITY INFORMATIONAL
::= { xupsTrapOidDefined 6 }
xupstdOutputOverload NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The ups has sensed an overload of greater than
106 percent. Tied to the 106% overload alarm."
--#SEVERITY MINOR
::= { xupsTrapOidDefined 7 }
xupstdInternalFailure NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"Some component of the ups - rectifier, inverter,
control panel has failed. Tied to alarms indi-
cating failure."
--#SEVERITY CRITICAL
::= { xupsTrapOidDefined 8 }
xupstdBatteryDischarged NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The Battery Totally Discharged Alarm has occurred."
--#SEVERITY CRITICAL
::= { xupsTrapOidDefined 9 }
xupstdInverterFailure NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The ups inverter is unavailable or malfunctioning due to an internal failure."
--#SEVERITY CRITICAL
::= { xupsTrapOidDefined 10 }
xupstdOnBypass NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The ups has gone on bypass for some reason."
--#SEVERITY CRITICAL
::= { xupsTrapOidDefined 11 }
xupstdBypassNotAvailable NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The ups bypass is unavailable"
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 12 }
xupstdOutputOff NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The ups output is switched off."
--#SEVERITY CRITICAL
::= { xupsTrapOidDefined 13 }
xupstdInputFailure NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The ups input power is incorrect in voltage,
frequency, or phase rotation."
--#SEVERITY MINOR
::= { xupsTrapOidDefined 14 }
xupstdBuildingAlarm NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"One of the defined building alarms has occurred."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 15 }
xupstdShutdownImminent NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The ups shutdown imminent alarm has occurred."
--#SEVERITY CRITICAL
::= { xupsTrapOidDefined 16 }
xupstdOnInverter NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The ups is returned to utility power running the inverter
after either a transfer to bypass or a run on battery."
--#SEVERITY INFORMATIONAL
::= { xupsTrapOidDefined 17 }
xupstdBreakerOpen NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"One of the UPS breakers or contactors has been opened."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 20 }
xupstdAlarmEntryAdded NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"An alarm not defined in the xups Well Known Alarms
(eg, an alarm defined in RFC1628)
has been added to the Alarm Table."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 21 }
xupstdAlarmEntryRemoved NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"An alarm not defined in the xups Well Known Alarms
has been removed from the Alarm Table."
--#SEVERITY INFORMATIONAL
::= { xupsTrapOidDefined 22 }
xupstdAlarmBatteryBad NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"One or more batteries have been determined to require replacement."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 23 }
xupstdOutputOffAsRequested NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The UPS has shutdown as requested, i.e., the output is off."
--#SEVERITY INFORMATIONAL
::= { xupsTrapOidDefined 24 }
xupstdDiagnosticTestFailed NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The result of the last diagnostic test indicates a failure."
--#SEVERITY MINOR
::= { xupsTrapOidDefined 25 }
xupstdCommunicationsLost NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"A problem has been encountered in the communications
between the agent and the UPS."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 26 }
xupstdUpsShutdownPending NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"An xupsControlOutputOffDelay countdown is underway."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 27 }
xupstdAlarmTestInProgress NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"A test is in progress, as initiated and indicated by the xupsTest Group.
When the test is complete, one of the following traps will be sent:
- xupstdDiagnosticTestFailed if the test fails,
- xupstdDiagnosticTestPassed on success, or
- xupstdAlarmEntryRemoved in other cases (e.g., Test Canceled)."
--#SEVERITY INFORMATIONAL
::= { xupsTrapOidDefined 28 }
-- Provide additional information with the AmbientTemp trap
xupstdAmbientTempBad NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage,
xupsEnvAmbientTemp, xupsEnvAmbientLowerLimit,
xupsEnvAmbientUpperLimit }
STATUS current
DESCRIPTION
"The ambient temperature, xupsEnvAmbientTemp, has fallen below
the set lower limit, xupsEnvAmbientLowerLimit, or has risen above
the set upper limit, xupsEnvAmbientUpperLimit."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 29 }
-- Added to support the ConnectUPS Web/SNMP card's ability to monitor contact(s)
xupstdContactActiveNotice NOTIFICATION-TYPE
OBJECTS { xupsContactIndex, xupsContactType, xupsContactState, xupsContactDescr }
STATUS current
DESCRIPTION
"The Contact indicated by xupsContactIndex is in its Active state.
The following are the situations that generate this trap:
For xupsContactType: and xupsContactState:
normallyOpen(1) and closedWithNotice(4)
normallyClosed(2) and openWithNotice(3)
anyChange(3) and openWithNotice(3) or closedWithNotice(4)"
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 30 }
xupstdContactInactiveNotice NOTIFICATION-TYPE
OBJECTS { xupsContactIndex, xupsContactType, xupsContactState, xupsContactDescr }
STATUS current
DESCRIPTION
"The Contact indicated by xupsContactIndex has changed to its Inactive state."
--#SEVERITY INFORMATIONAL
::= { xupsTrapOidDefined 31 }
xupstdLossOfRedundancy NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"A parallel UPS system is no longer operating in N+1 redundant mode;
this may be due to module failure or removal, or due to overloading."
--#SEVERITY MINOR
::= { xupsTrapOidDefined 32 }
xupstdAlarmTempBad NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"An internal temperature is out of tolerance."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 33 }
xupstdAlarmChargerFailed NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"An uncorrected problem has been detected within the UPS charger subsystem."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 34 }
xupstdAlarmFanFailure NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The failure of one or more fans in the UPS has been detected."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 35 }
xupstdAlarmFuseFailure NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The failure of one or more fuses has been detected."
--#SEVERITY CRITICAL
::= { xupsTrapOidDefined 36 }
xupstdPowerSwitchBad NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"A Relay, Contactor, or Breaker has failed."
--#SEVERITY CRITICAL
::= { xupsTrapOidDefined 37 }
xupstdModuleFailure NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"One module in a parallel or composite system has failed."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 38 }
-- xupsInputSource added to this trap's var list
xupstdOnAlternatePowerSource NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage, xupsInputSource }
STATUS current
DESCRIPTION
"The system is being powered by its Alternate Power Source, such as a
Secondary utility feed (on a dual AC input UPS), generator, flywheel,
or fuel cell."
--#SEVERITY MINOR
::= { xupsTrapOidDefined 39 }
xupstdAltPowerNotAvailable NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"On systems with a separate alternate power source (eg, dual AC inputs),
that alternate power source is currently not available. This could be
a problem if the primary power source (eg, utility) fails for a period
of time longer than that for which the internal batteries can supply power."
--#SEVERITY MINOR
::= { xupsTrapOidDefined 40 }
xupstdNoticeCondition NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"Some Notice condition exists which is not covered by the other traps.
This is like an xupstdInternalFailure, but at a lower severity level."
--#SEVERITY MINOR
::= { xupsTrapOidDefined 41 }
-- Added to provide additional information with the RemoteTemp and RemoteHumidity
xupstdRemoteTempBad NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage,
xupsEnvRemoteTemp, xupsEnvRemoteTempLowerLimit,
xupsEnvRemoteTempUpperLimit }
STATUS current
DESCRIPTION
"The remote temperature, xupsEnvRemoteTemp, has fallen below
the set lower limit, xupsEnvRemoteTempLowerLimit, or has risen above
the set upper limit, xupsEnvRemoteTempUpperLimit."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 42 }
xupstdRemoteHumidityBad NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage,
xupsEnvRemoteHumidity, xupsEnvRemoteHumidityLowerLimit,
xupsEnvRemoteHumidityUpperLimit }
STATUS current
DESCRIPTION
"The remote temperature, xupsEnvRemoteHumidity, has fallen below
the set lower limit, xupsEnvRemoteHumidityLowerLimit, or has risen above
the set upper limit, xupsEnvRemoteHumidityUpperLimit."
--#SEVERITY MINOR
::= { xupsTrapOidDefined 43 }
xupstdHeartbeat NOTIFICATION-TYPE
OBJECTS { xupsInputSource, xupsOutputSource, xupsAlarms }
STATUS current
DESCRIPTION
"A periodic status trap message. It is sent at an interval
set by object xupsHeartbeatMinsInterval.
The included variables provide a brief statement of the UPS status."
--#SEVERITY INFORMATIONAL
::= { xupsTrapOidDefined 44 }
xupstdDiagnosticTestPassed NOTIFICATION-TYPE
OBJECTS { xupsTestBatteryStatus, xupsLastGeneralTest, xupsLastGeneralTestResult }
STATUS current
DESCRIPTION
"A diagnostic test just completed, and its result is Passed.
The included variables provide additional information on the test."
--#SEVERITY INFORMATIONAL
::= { xupsTrapOidDefined 45 }
xupstdOutputBad NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The output condition (other than OutputOverload) is out of tolerance."
--#SEVERITY CRITICAL
::= { xupsTrapOidDefined 46 }
xupstdAwaitingPower NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The UPS output is off and the UPS is awaiting the return of input power."
--#SEVERITY MINOR
::= { xupsTrapOidDefined 47 }
xupstdOnMaintenanceBypass NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The UPS has been placed on Maintenance / Manual Bypass by an operator."
--#SEVERITY MAJOR
::= { xupsTrapOidDefined 48 }
xupstdCommEstablished NOTIFICATION-TYPE
OBJECTS { xupsIdentModel, xupsOutputSource }
STATUS current
DESCRIPTION
"This trap is sent when the SNMP agent first establishes a communication
link with the UPS.
The included variables provide identification and UPS status information."
--#SEVERITY INFORMATIONAL
::= { xupsTrapOidDefined 49 }
xupstdAgentDown NOTIFICATION-TYPE
-- OBJECTS { (none) }
STATUS current
DESCRIPTION
"This trap is sent when the SNMP agent is exiting or closing down gracefully.
This may be triggered by a signal from the OS to stop this process. In many
implementations, it will be followed quickly by a restart of this vital process."
--#SEVERITY MINOR
::= { xupsTrapOidDefined 50 }
-- New traps now managed by the Network-M2 card
xupstdOutputNotProtected NOTIFICATION-TYPE
OBJECTS { xupsAlarmID, xupsAlarmDescr, xupsTrapMessage }
STATUS current
DESCRIPTION
"The ups output is not protectet for any reason in the UPS."
--#SEVERITY CRITICAL
::= { xupsTrapOidDefined 51 }
xupstdTestTrap NOTIFICATION-TYPE
OBJECTS { sysName, xupsTrapMessage }
STATUS current
DESCRIPTION
"This trap is sent to the trap receivers to check proper reception of traps."
--#SEVERITY INFORMATIONAL
::= { xupsTrapOidDefined 100 }
--
-- Conformance-related definitions
-- (Defined mostly to satisfy the MIB checkers.)
--
xupsConformance OBJECT IDENTIFIER ::= { xupsMIB 100 }
xupsIdentFullGroup OBJECT-GROUP
OBJECTS { xupsIdentManufacturer, xupsIdentModel,
xupsIdentSoftwareVersion, xupsIdentOemCode,
xupsIdentPartNumber, xupsIdentSerialNumber }
STATUS current
DESCRIPTION
"The Full set of xupsIdent subgroup objects."
::= { xupsConformance 2 }
xupsBatteryFullGroup OBJECT-GROUP
OBJECTS { xupsBatTimeRemaining, xupsBatVoltage, xupsBatCurrent,
xupsBatCapacity, xupsBatteryAbmStatus, xupsBatteryLastReplacedDate,
xupsBatteryFailure, xupsBatteryNotPresent, xupsBatteryAged, xupsBatteryLowCapacity }
STATUS current
DESCRIPTION
"The Full set of xupsBattery subgroup objects."
::= { xupsConformance 3 }
xupsInputFullGroup OBJECT-GROUP
OBJECTS { xupsInputFrequency, xupsInputLineBads, xupsInputNumPhases,
xupsInputSource, xupsDualInputStatus, xupsSecondaryInputWatch, xupsInputStatus }
STATUS current
DESCRIPTION
"The Full set of xupsInput subgroup objects."
::= { xupsConformance 4 }
xupsInputTableFullGroup OBJECT-GROUP
OBJECTS { xupsInputPhase, xupsInputVoltage, xupsInputCurrent, xupsInputWatts,
xupsInputId, xupsInputName, xupsInputCurrentHighPrecision, xupsInputVoltagePhaseToPhase }
STATUS current
DESCRIPTION
"The Full set of xupsInputTable subgroup objects."
::= { xupsConformance 5 }
xupsOutputFullGroup OBJECT-GROUP
OBJECTS { xupsOutputLoad, xupsOutputFrequency, xupsOutputNumPhases, xupsOutputSource,
xupsOutputHourlyPowerUsage, xupsOutputCumulativePowerUsage, xupsOutputCumulativePowerUsageTimer, xupsOutputStatus }
STATUS current
DESCRIPTION
"The Full set of xupsOutput subgroup objects."
::= { xupsConformance 6 }
xupsOutputTableFullGroup OBJECT-GROUP
OBJECTS { xupsOutputPhase, xupsOutputVoltage, xupsOutputCurrent, xupsOutputWatts,
xupsOutputId, xupsOutputName, xupsOutputCurrentHighPrecision, xupsOutputPercentLoad, xupsOutputVA, xupsOutputVoltagePhaseToPhase }
STATUS current
DESCRIPTION
"The Full set of xupsOutputTable subgroup objects."
::= { xupsConformance 7 }
xupsBypassFullGroup OBJECT-GROUP
OBJECTS { xupsBypassFrequency, xupsBypassNumPhases, xupsBypassPhase, xupsBypassVoltage, xupsBypassVoltagePhaseToPhase }
STATUS current
DESCRIPTION
"The Full set of xupsBypass subgroup objects."
::= { xupsConformance 8 }
xupsEnvironmentFullGroup OBJECT-GROUP
OBJECTS { xupsEnvAmbientTemp, xupsEnvAmbientLowerLimit,
xupsEnvAmbientUpperLimit, xupsEnvAmbientHumidity }
STATUS current
DESCRIPTION
"The Full set of xupsEnvironment subgroup objects."
::= { xupsConformance 9 }
xupsAlarmFullGroup OBJECT-GROUP
OBJECTS { xupsAlarms, xupsAlarmID, xupsAlarmDescr, xupsAlarmTime }
STATUS current
DESCRIPTION
"The Full set of xupsAlarm subgroup objects."
::= { xupsConformance 10 }
xupsAlarmEventsFullGroup OBJECT-GROUP
OBJECTS { xupsAlarmNumEvents, xupsAlarmEventMsg }
STATUS current
DESCRIPTION
"The Full set of Alarm/Event history subgroup objects."
::= { xupsConformance 11 }
xupsTestFullGroup OBJECT-GROUP
OBJECTS { xupsTestStart, xupsTestBatteryStatus, xupsLastGeneralTest,
xupsLastGeneralTestResult, xupsTestTrap }
STATUS current
DESCRIPTION
"The Full set of xupsTest subgroup objects."
::= { xupsConformance 12 }
xupsControlFullGroup OBJECT-GROUP
OBJECTS { xupsControlOutputOffDelay, xupsControlOutputOnDelay,
xupsControlOutputOffTrapDelay, xupsControlToBypassDelay,
xupsLoadShedSecsWithRestart, xupsSwitchable }
STATUS current
DESCRIPTION
"The Full set of xupsControl subgroup objects."
::= { xupsConformance 13 }
xupsConfigFullGroup OBJECT-GROUP
OBJECTS { xupsConfigOutputVoltage, xupsConfigInputVoltage, xupsConfigOutputWatts,
xupsConfigOutputFreq, xupsConfigDateAndTime, xupsConfigLowOutputVoltageLimit,
xupsConfigHighOutputVoltageLimit, xupsConfigInstallDate }
STATUS current
DESCRIPTION
"The Full set of xupsConfig subgroup objects."
::= { xupsConformance 14 }
xupsTrapControlFullGroup OBJECT-GROUP
OBJECTS { xupsMaxTrapLevel, xupsSendTrapType, xupsTrapMessage,
xupsHeartbeatMinsInterval }
STATUS current
DESCRIPTION
"The Full set of xupsTrapControl subgroup objects."
::= { xupsConformance 15 }
xupsRecepFullGroup OBJECT-GROUP
OBJECTS { xupsNumReceptacles, xupsRecepIndex, xupsRecepStatus,
xupsRecepOffDelaySecs, xupsRecepOnDelaySecs,
xupsRecepAutoOffDelay, xupsRecepAutoOnDelay, xupsRecepShedSecsWithRestart,
xupsRecepHourlyPowerUsage, xupsRecepCumulativePowerUsage, xupsRecepCumulativePowerUsageTimer }
STATUS current
DESCRIPTION
"The Full set of xupsRecep subgroup objects."
::= { xupsConformance 16 }
xupsTopologyFullGroup OBJECT-GROUP
OBJECTS { xupsTopologyType, xupsTopoMachineCode,
xupsTopoUnitNumber, xupsTopoPowerStrategy }
STATUS current
DESCRIPTION
"The Full set of xupsTopology subgroup objects."
::= { xupsConformance 17 }
xupstdNotifyGroup NOTIFICATION-GROUP
NOTIFICATIONS { xupstdControlOff, xupstdControlOn, xupstdOnBattery, xupstdLowBattery,
xupstdUtilityPowerRestored, xupstdReturnFromLowBattery,
xupstdOutputOverload, xupstdInternalFailure, xupstdBatteryDischarged,
xupstdInverterFailure, xupstdOnBypass, xupstdBypassNotAvailable,
xupstdOutputOff, xupstdInputFailure, xupstdBuildingAlarm,
xupstdShutdownImminent, xupstdOnInverter, xupstdBreakerOpen,
xupstdAlarmEntryAdded, xupstdAlarmEntryRemoved, xupstdAlarmBatteryBad,
xupstdOutputOffAsRequested, xupstdDiagnosticTestFailed,
xupstdCommunicationsLost, xupstdUpsShutdownPending, xupstdAlarmTempBad,
xupstdAlarmTestInProgress, xupstdAmbientTempBad, xupstdLossOfRedundancy,
xupstdAlarmChargerFailed, xupstdAlarmFanFailure, xupstdAlarmFuseFailure,
xupstdPowerSwitchBad, xupstdModuleFailure, xupstdOnAlternatePowerSource,
xupstdAltPowerNotAvailable, xupstdNoticeCondition, xupstdHeartbeat,
xupstdDiagnosticTestPassed, xupstdOutputBad, xupstdAwaitingPower,
xupstdOnMaintenanceBypass, xupstdCommEstablished, xupstdAgentDown,
xupstdOutputNotProtected, xupstdTestTrap }
STATUS current
DESCRIPTION
"The Alarm and Event notifications from the xupsTrapDefined source (xupstd)."
::= { xupsConformance 18 }
xupstdEMPNotifyGroup NOTIFICATION-GROUP
NOTIFICATIONS { xupstdContactActiveNotice, xupstdContactInactiveNotice,
xupstdRemoteTempBad, xupstdRemoteHumidityBad }
STATUS current
DESCRIPTION
"The EMP's Alarm and Event notifications from the xupsTrapDefined source (xupstd)."
::= { xupsConformance 19 }
xupsMibFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"A compliance statement for all of everything in this MIB."
MODULE -- this module
MANDATORY-GROUPS { xupsIdentFullGroup, xupsBatteryFullGroup, xupsInputFullGroup,
xupsInputTableFullGroup, xupsOutputFullGroup, xupsOutputTableFullGroup,
xupsBypassFullGroup, xupsEnvironmentFullGroup, xupsAlarmFullGroup,
xupsAlarmEventsFullGroup, xupsTestFullGroup, xupsControlFullGroup,
xupsConfigFullGroup, xupsTrapControlFullGroup, xupsRecepFullGroup,
xupsTopologyFullGroup, xupstdNotifyGroup, xupstdEMPNotifyGroup,
xupsBypassTableFullGroup, xupsInputTotalFullGroup, xupsOutputTotalFullGroup,
xupsBypassTotalFullGroup }
::= { xupsConformance 20 }
xupsDeprecatedGroup OBJECT-GROUP
OBJECTS { xupsAlarmEventDateAndTime, xupsAlarmEventKind,
xupsAlarmEventDescr, xupsControlOutputOnTrapDelay }
STATUS deprecated
DESCRIPTION
"Contains objects which are now deprecated."
::= { xupsConformance 21 }
xupsBypassTableFullGroup OBJECT-GROUP
OBJECTS { xupsBypassId, xupsBypassName, xupsBypassCurrentHighPrecision, xupsBypassWatts}
STATUS current
DESCRIPTION
"The Full set of xupsBypassTable subgroup objects."
::= { xupsConformance 22 }
xupsInputTotalFullGroup OBJECT-GROUP
OBJECTS { xupsInputAverageVoltage, xupsInputTotalCurrent, xupsInputTotalWatts,
xupsInputTotalVA, xupsInputAveragePowerFactor }
STATUS current
DESCRIPTION
"The Full set of xupsInputTotal subgroup objects."
::= { xupsConformance 23 }
xupsOutputTotalFullGroup OBJECT-GROUP
OBJECTS { xupsOutputAverageVoltage, xupsOutputTotalCurrent, xupsOutputTotalWatts,
xupsOutputTotalVA, xupsOutputAveragePowerFactor }
STATUS current
DESCRIPTION
"The Full set of xupsOutputTotal subgroup objects."
::= { xupsConformance 24 }
xupsBypassTotalFullGroup OBJECT-GROUP
OBJECTS { xupsBypassAverageVoltage, xupsBypassTotalCurrent, xupsBypassTotalWatts,
xupsBypassTotalVA, xupsBypassAveragePowerFactor }
STATUS current
DESCRIPTION
"The Full set of xupsOutputTotal subgroup objects."
::= { xupsConformance 25 }
xupsAgentFullGroup OBJECT-GROUP
OBJECTS { xupsAgentManufacturer, xupsAgentModel,
xupsAgentSoftwareVersion, xupsAgentPartNumber, xupsAgentSerialNumber }
STATUS current
DESCRIPTION
"The Full set of xupsAgent subgroup objects."
::= { xupsConformance 26 }
END